Intel E3815 FH8065301567411 Data Sheet
Product codes
FH8065301567411
Intel
®
Atom™ Processor E3800 Product Family
Datasheet
1127
15.8.9
reg_gpd_gp_reg_reg_gp_sp_stream_stat_irq_cond_type
(gpd_gp_reg_reg_gp_sp_stream_stat_irq_cond)—Offset 20h
Access Method
Default: 00000000h
10
0h
RO
MOD_STR_MON_SP2SIF_valid:
Returns the value 1 if there is a command available
on the command fifo between the SP and the secondary input formatter. Returns the
value 0 if the command FIFO for the secondary input formatter is empty.
9
1h
RO
MOD_STR_MON_SIF2SP_accept:
Returns the value 1 if the acknowledge FIFO
between the secondary input formatter and the SP can accept an acknowledge token
from the secondary input formatter. Returns the value 0 if this FIFO is full.
8
0h
RO
MOD_STR_MON_SIF2SP_valid:
Returns the value 1 if the secondary input formatter
sends an acknowledge token using its acknowledge output port connected to the
acknowledge FIFO between the secondary input formatter and the SP. Returns the value
0 if the secondary input formatter does not send an acknowledge token to this FIFO.
7
0h
RO
MOD_STR_MON_CELLS2PIFB_accept:
Returns the value 1 if primary input formatter
B can accept a command token from the command FIFO between the ISP/SP and the
primary input formatter B. Returns the value 0 if the primary input formatter B cannot
accept a command token.
6
0h
RO
MOD_STR_MON_CELLS2PIFB_valid:
Returns the value 1 if there is a command
available on the command fifo between SP/ISP and the primary input formatter B.
Returns the value 0 if the command FIFO for the primary input formatter B is empty.
5
1h
RO
MOD_STR_MON_PIFB2CELLS_accept:
Returns the value 1 if the acknowledge FIFO
between the primary input formatter B and the ISP/SP can accept an acknowledge
token from the primary input formatter B. Returns the value 0 if this command FIFO is
full.
4
0h
RO
MOD_STR_MON_PIFB2CELLS_valid:
Returns the value 1 if primary input formatter
B sends an acknowledge token using the streaming port connected to the acknowledge
FIFO to the ISP/SP. Returns the value 0 if the primary input formatter B does not send
an acknowledge token to this FIFO.
3
0h
RO
MOD_STR_MON_CELLS2PIFA_accept:
Returns the value 1 if primary input
formatter A can accept a command token from the command FIFO between the ISP/SP
and the primary input formatter A. Returns the value 0 if the primary input formatter A
cannot accept a command token.
2
0h
RO
MOD_STR_MON_CELLS2PIFA_valid:
Returns the value 1 if there is a command
available on the command fifo between SP/ISP and the primary input formatter A.
Returns the value 0 if the command FIFO for the primary input formatter A is empty.
1
1h
RO
MOD_STR_MON_PIFA2CELLS_accept:
Returns the value 1 if the acknowledge FIFO
between the primary input formatter A and the ISP/SP can accept an acknowledge
token from the primary input formatter A. Returns the value 0 if this command FIFO is
full.
0
0h
RO
MOD_STR_MON_PIFA2CELLS_valid:
Returns the value 1 if primary input formatter
A sends an acknowledge token using the streaming port connected to the acknowledge
FIFO to the ISP/SP. Returns the value 0 if the primary input formatter A does not send
an acknowledge token to this FIFO.
Bit
Range
Default &
Access
Description
Type:
Memory Mapped I/O Register
(Size: 32 bits)
gpd_gp_reg_reg_gp_sp_stream_stat_irq_cond:
ISPMMADR Type:
PCI Configuration Register (Size: 32 bits)
ISPMMADR Reference:
[B:0, D:3, F:0] + 10h