63 
Phasing, Power-On Mode: Ixx80, Ixx73, Ixx74, Ixx81, Ixx91 
I180=0 I173=0 I174=0  ; 
I280=0 I273=0 I274=0  ; 
I380=0 I373=0 I374=0  ; 
I480=0 I473=0 I474=0  ; 
 
  
I181=$3503 
 
; Motor 1 Power-On Commutation, Integrated Output #1   
I281=$3506 
 
; Motor 2 Power-On Commutation, Integrated Output #2 
I381=$3509 
 
; Motor 3 Power-On Commutation, Integrated Output #3 
I481=$350C 
 
; Motor 4 Power-On Commutation, Integrated Output #4 
I191,4,100=$500000 
; Mtrs 1-4 Pwr-on Pos. format Read 16 (11+5) bits of X register Ixx81 
 
Position-
Loop PID Gains: Ixx30…Ixx39 
I130,4,100=1024  
; Motor 1-4 PID Proportional Gain  
I131,4,100=0    
; Motor 1-4 PID Derivitive Gain 
I132,4,100=85   
; Motor 1-4 PID Velocity Feedforward Gain 
I133,4,100=1024  
; Motor 1-4 PID Integral Gain  
I134,4,100=1    
; Motor 1-4 PID Integration Mode 
I135,4,100=0 
 
; Motor 1-4 PID Acceleration Feedforward Gain 
I136,4,100=0 
 
; Motor 1-4 PID Notch Filter Coefficient N1 
I137,4,100=0 
 
; Motor 1-4 PID Notch Filter Coefficient N2 
I138,4,100=0 
 
; Motor 1-4 PID Notch Filter Coefficient D1   
I139,4,100=0 
 
; Motor 1-4 PID Notch Filter Coefficient D2