Delta Tau TURBO CLIPPER DRIVE User Manual

Page of 87
Turbo Clipper Drive User Manual 
 
Motor Setup Guidelines 
64 
Current-Loop Gains: Ixx61, Ixx62, Ixx76 
The current-loop tuning can be performed as in any Turbo PMAC digital current loop setup. The 
PMACTuningPro2 automatic or interactive utility can be used to fine-tune the current loop gains.      
Ixx61=0.005, Ixx62=0, and Ixx76=0.05 is a good/safe starting point for interactive current-loop 
tuning. Typically, an acceptable current-loop step response would look like the following:  
 
 
 
Number Of Counts Per Revolution (Stepper Motors) 
With a count equal to a micro-step, and 512 micro-steps per 1.8-degree full step (2048 per 
cycle), you should expect to see 360*512/1.8= 102,400 counts per revolution of the motor. 
 
 
 
Note 
Some stepper motors have unconventional specifications making 
top speeds unattainable with the basic micro-stepping technique. 
Adjusting  the  direct  current  on  the  fly  might  be  necessary  (i.e. 
using open servo).