Ixx56  Motor xx Commutation Delay Compensation 
Range:   
0.0 – 1.0 
Units:   
(Ixx09*32/2048) commutation cycles/(counts/servo update) 
Default: 
Ixx56 permits the Turbo PMAC to compensate lags in the electrical circuits of the motor phases, and/or 
for calculation delays in the commutation of Motor xx, therefore improving high-velocity performance.  
The compensation is simply Ixx56 multiplied by the motor velocity. 
Ixx56 is only used if Turbo PMAC is commutating Motor xx (Ixx01=1).  It should be only be used for the 
commutation of synchronous motors (Ixx78=0) such as permanent magnet brushless motors.  Ixx56 
should be set to 0 for asynchronous motors (Ixx78>0) such as AC induction motors. 
If Turbo PMAC is commutating Motor xx, but not closing the current loop (Ixx82=0), Ixx56 can improve 
performance typically starting at a few thousand RPM, because it compensates for inductive lags in the 
motor windings.  If Turbo PMAC is also closing the current loop for Motor xx (Ixx82>0; Turbo PMAC2 
only), the DC field-frame current loop closure compensates for inductive lags, and only small calculation 
delays need to be compensated; these are usually not significant until well over 10,000 rpm. 
This parameter is best set experimentally by running the motor at high speeds, and finding the setting that 
minimizes the current draw of the motor. 
Example 
On a 4-pole motor with a 512-line encoder and “times-4” decode, it is desired to have an advance of 5 
degrees (electrical) at a motor speed of 30,000 rpm.  The Ixx56 advance gain converts from speed, 
expressed in (1/[Ixx08*32]) counts per servo cycle, to advance, expressed in (1/2048) commutation 
cycles.   
First convert our speed to these units: 
ct
cts
Ixx
rev
cts
s
servocycle
rev
]
32
*
08
/[
1
32
*
96
*
2048
*
2260
sec
*
sec
60
min
*
min
000
,
30
 
servocycle
cts
Ixx
]
32
*
08
/[
1
616
,
391
,
1
 
Next, convert our desired advance to these units: 
)
2048
/
1
(
44
.
28
360
)
2048
/
1
(
2048
*
5
commcycle
e
commcycle
e
o
o
 
Finally, compute Ixx56 as the ratio of advance to speed: 
0000204
.
0
616
,
391
,
1
44
.
28
56
Ixx
 
Ixx57  Motor xx Continuous Current Limit 
Range:   
-32,768 – 32,767 
Units:    
16-bit DAC/ADC bit equivalent 
Default: 
Ixx57 sets the magnitude of the maximum continuous current limit for Turbo PMAC’s integrated current 
limiting function, when that function is active (Ixx58 must be greater than 0 for the integrated current 
limit to be active).  If Turbo PMAC is closing a digital current loop for the motor, it uses actual current 
measurements for this function; otherwise, it uses commanded current values.  If the magnitude of the