Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC Variable and Command Summary 
 25 
Global Status Commands 
<CTRL-B> 
– Report 8 motor status words to host 
<CTRL-C> 
– Report all coordinate system status words to host 
<CTRL-F> 
– Report 8 motor following errors (unscaled) 
<CTRL-G> 
– Report global status words in binary form 
<CTRL-P> 
– Report 8 motor positions (unscaled) 
<CTRL-V> 
– Report 8 filtered motor velocities (unscaled) 
??? – Report global status words in hex ASCII 
CID – Report card ID (part) number 
CPU – Report model of CPU used 
DATE – Report release date of firmware version used 
IDNUMBER 
– Report Option 18 electronic identification number 
LIST 
– Report contents of open program buffer 
LIST PROGRAM {constant} 
– Report contents of specified motion program 
LIST PLC {constant} 
– Report contents of specified PLC program 
SID 
– Report Option 18 electronic identification number 
SIZE – Report size of open memory in words  
STN 
– Report MACRO-ring station-order number 
TIME – Report present time  
TODAY – Report present date  
TYPE – Report type of PMAC  
VERSION – Report firmware revision level 
VID 
– Report vendor ID number 
Register Access Commands 
R{address}[,{constant}] – Report contents of specified memory word address [or specified 
range of addresses] in decimal 
RH{address}[,{constant}] – Report contents of specified memory word address [or specified 
range of addresses] in hex 
W{address},{constant}[,{constant}..] – Write value to specified memory word address 
[or values to range] 
PLC Control Commands 
ENABLE PLC{constant}[,{constant}...] – Enable operation of specified interpreted PLC 
program[s], starting at top of scan 
DISABLE PLC{constant}[,{constant}...] – Disable operation of specified interpreted PLC 
program[s] 
PAUSE PLC{constant}[,{constant}...] – Suspend operation of specified interpreted PLC 
program[s] 
RESUME PLC{constant}[,{constant}...] – Enable operation of specified interpreted PLC 
program[s], starting at paused point 
ENABLE PLCC{constant}[,{constant}...] – Disable operation of specified compiled PLC 
program[s] 
DISABLE PLCC{constant}[,{constant}...] –- Disable operation of specified compiled PLC 
program[s]