Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC On-line Command Specification 
 345 
The contents are reported in ASCII text form.  If I9 is 0 or 2, the contents are reported in short form (e.g. 
ENDW).  If I9 is 1 or 3, the contents are reported in long form (e.g. ENDWHILE). 
If the inverse kinematic program requested by this command does not exist in Turbo PMAC, Turbo 
PMAC will reject this command (reporting an ERR003 if I6 is 1 or 3). 
Inverse kinematic programs can be protected by password.  If there is a password for the Turbo PMAC, 
and the password has not been given, Turbo PMAC will reject this command (reporting an ERR002 if I6 
is 1 or 3). 
See Also: 
Kinematic Calculations 
I-variable Isx50 
On-line commands LIST FORWARDOPEN FORWARDOPEN INVERSE 
LIST LDS 
Function: 
List Linking Addresses of Ladder Functions  
Scope: 
Global 
Syntax: 
LIST LDS 
This command causes Turbo PMAC to list the addresses of the internal routines that the special ladder-
logic PLC cross-compiler needs to properly compile and link programs.  This command is used 
automatically by the cross-compiler; a user only needs it directly for special debugging. 
See Also: 
On-line commands LIST LINK  
LIST LINK 
Function: 
List Linking Addresses of Internal Turbo PMAC Routines 
Scope: 
Global 
Syntax: 
LIST LINK 
This command causes Turbo PMAC to list the addresses of the internal routines that the PLC cross-
compiler needs to properly compile and link its programs.  This command is used automatically by the 
PLC cross-compiler in the Executive program.   
For the standalone DOS cross-compiler, the ASCII characters of Turbo PMAC's response to this 
command must be contained in a file named LISTLINK.TXT in the same directory and subdirectory as 
the cross-compiler.  Each separate version of Turbo PMAC's firmware potentially has different addresses 
for these routines, so a new LISTLINK.TXT file must be created any time the Turbo PMAC firmware is 
updated, even for a minor change such as from V2.01A to V2.01B. 
Example: 
LIST LINK 
; Request linking addresses 
004532 004A97 005619 005F21 0062FE 0063A4 
 
; Turbo PMAC responds 
See Also: 
Compiled PLCs (Writing a PLC Program) 
LIST PC 
Function: 
List Program at Program Counter 
Scope: 
Coordinate-system specific 
Syntax: 
LIST PC[,[{constant}]] 
where: 
 
{constant} is a positive integer representing the number of words in the program to be listed