Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC On-line Command Specification 
 398 
 
{hh} is the 2-digit representation of the hour (00 <= {hh} <= 23) 
 
{mm} is the 2-digit representation of the minute (00 <= {mm} <= 59) 
 
{ss} is the 2-digit representation of the second (00 <= {ss} <= 59) 
This command sets the current time in Turbo PMAC’s active (volatile) memory.  The time is entered in 
the international 24-hour clock format, as hour/minute/second.   
Entering of the seconds is optional; if the seconds are not entered, Turbo PMAC will use 0 seconds.  Date 
and time automatically advance in Turbo PMAC’s active memory, and the present time can be queried at 
any time with the TIME command. 
This time information is not retained through a power-down or board reset unless the Option 18B non-
volatile clock/calendar IC is present and the active date and time information has been copied into the 
non-volatile IC with the UPDATE command. 
The present date can be set with the TODAY={date} command. 
Examples: 
TIME=08:30 
; Set time to 8:30:00 am 
TIME=17:45:24 
; Set time to 5:45:24 pm 
TODAY 
Function: 
Report present date 
Scope: 
Global 
Syntax: 
TODAY 
This command causes Turbo PMAC to report the current date.  The date is reported in the North 
American format: 
{day} {mm}/{dd}/{yyyy} 
where: 
 
{day} is the 3-letter abbreviation for the day of the week 
 
{mm} is the 2-digit representation of the month 
 
{dd} is the 2-digit representation of the day of the month 
 
{yyyy} is the 4-digit representation of the year 
The date must originally have been set with the TODAY={date} command for an accurate date to be 
reported here.  If the Option 18B non-volatile clock/calendar IC is present, this IC will retain and advance 
the date information even while no external power is applied.  On power-up or reset of the Turbo PMAC, 
the present date and time are copied into active memory, and then they advance automatically in the 
active memory.  The TODAY command reports from active memory. 
If the Option 18B is not present, Turbo PMAC will default to Jan. 1, 2000, at 00:00:00, on power-
up/reset, and date and time will advance in active memory from this point.  The actual date may be loaded 
into active memory after power-up/reset, and the date and time will advance from this point. 
Note: 
The 4-digit representation of the year eliminates possible Year 2000 problems in 
user code processing the date information. 
Examples: 
TODAY 
WED 09/09/1998 
TODAY 
FRI 04/22/2000