Delta Tau GEO BRICK LV User Manual

Page of 271
Geo Brick LV User Manual
 
PinOuts and Software Setup 
 149 
+5V ENC PWR (Alternate Encoder Power) 
Typically,  feedback  devices  are  powered  up  through  the  X1-X8  connectors  on  the  Geo  Brick  LV  using 
the internal +5VDC power supply. In some cases, feedback devices consume power excessively and risk 
of surpassing the internal power supply limitation. 
 
This  connector  provides  an  alternate  mean  to  power-up  the  feedback  devices  (+5V  only)  if  the  total 
encoder budget exceeds the specified thresholds. 
 
 
Note 
Encoders  requiring  greater  than  +5VDC  power  must  be  supplied 
externally, and NOT through the X1-X8 connectors NOR through this 
connector.    
 
G B D x
-
x
x
-
x
x
x
-
x
x
x
x
x
x
x
x
Add-in Board Options
 
 
The add-in board (any non-zero digit in the highlighted part number field) for MACRO and special 
feedback requires an additional ~ 0.5A (+5V power). This alters the total power available for encoders.    
 
The newer models of the Geo Brick LV have a beefier power supply and can handle more (+5V) power 
drain. The following tables summarize the +5V power available for encoder devices (X1-X8):  
 
!
Caution 
The  maximum  current draw  out of a single  encoder channel  must not 
exceed 750 mA.  
 
Geo Brick LV Model 
Total Encoder Power 
Available [Amps] 
Power Per Encoder 
(4 x channels) [mA] 
Power Per Encoder 
( 8 x channels) [mA] 
Older 
Newer 
Older 
Newer 
Older 
Newer 
Without Add-in Board 
1.5 
375 
500 
188 
250 
With Add-in Board 
1.5 
250 
375 
125 
188 
 
 
Note 
The newer models of the Geo Brick LV were introduced in October of 
2012  and  can  be  recognized  by  the  5-pin  terminal  block  STO 
connector which was not previously available.