indicate that, although output is being produced, there is a problem that could require 
attention. The most common conditions that produce alarms or warnings are listed in 
.
Table 3.2: iPump 562 Front Panel Status LED Alarm and Warning Indications
Diagterm 
Terminal 
(Commands)
The Serial Port (RS-232) can be used to connect to a terminal console. After the IRD is 
powered on, a diagterm command-line interface (CLI) can be used to monitor and control 
the system. For more information on diagterm and syntax of the individual commands, 
please see an appendix. 
 illustrates the 
Help 
screen on the diagterm terminal.
 Figure 3.3:   Diagterm Terminal Help Screen
Mode
LED Status
Condition
Alarm
Red blink = 2
No carrier
Red blink = 3
No RF signal
Red blink = 4
In recovery
Red blink = 5
Eb/No alarm
Red blink = 11
Not authorized
Warning
Amber blink = 1
No response from SEC_MICRO
Amber blink = 2
Marginal Eb/No
Amber blink = 4
Selected audio not available
Amber blink = 5
RF too low
Amber blink = 6
RF too high
Amber blink = 7
Application download failed
Normal
Green
Normal operation