Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
5 -  5 
5. PARAMETERS 
 
5.1.4 Selection of regenerative option 
Parameter 
Initial 
value 
Unit 
Setting 
range 
Control mode 
No. Symbol 
Name 
Position Speed Torque
PA02 *REG Regenerative 
option 
0000h 
 
Refer to 
the text. 
 
 
 
 
POINT 
 
Turn off the power and then on again after setting the parameter to validate the 
parameter value. 
Incorrect setting may cause the regenerative option to burn. 
If the regenerative option selected is not for use with the servo amplifier, 
parameter error (AL.37) occurs.  
For a drive unit of 30kW or more, always set the parameter to "
00" since 
selecting regenerative option is carried out by the converter unit. 
 
 
Set this parameter when using the regenerative option, brake unit, power regenerative converter, or power 
regenerative common converter. 
Selection of regenerative option
00: Regenerative option is not used
        For servo amplifier of 100W, regenerative resistor is not used.
        For servo amplifier of 200 to 7kW, built-in regenerative resistor is used.
        Supplied regenerative resistors or regenerative option is used with
        the servo amplifier of 11k to 22kW.
        For a drive unit of 30kW or more, select regenerative option by the
        converter unit.
01: FR-BU2-(H)  FR-RC-(H)  FR-CV-(H)
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50(Cooling fan is required)
08: MR-RB31
09: MR-RB51(Cooling fan is required)
80: MR-RB1H-4
81: MR-RB3M-4(Cooling fan is required)
82: MR-RB3G-4(Cooling fan is required)
83: MR-RB5G-4(Cooling fanis required)
84: MR-RB34-4(Cooling fanis required)
85: MR-RB54-4(Cooling fanis required)
FA: When the supplied regenerative resistor is cooled by the cooling fan to  
       increase the ability with the servo amplifier of 11k to 22kW.      
0 0
Parameter No.PA02