Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
5 -  13 
5. PARAMETERS 
 
(2) Auto tuning response (parameter No.PA09) 
If the machine hunts or generates large gear sound, decrease the set value. To improve performance, e.g. 
shorten the settling time, increase the set value. 
 
Setting Response 
Guideline for machine 
resonance frequency [Hz] 
 Setting
Response 
Guideline for machine 
resonance frequency [Hz] 
Low response 
10.0 
 
17 
Middle response 
67.1 
 
11.3  
18 
75.6 
3 12.7 
 
19 85.2 
4 14.3 
 
20 95.9 
5 16.1 
 
21 108.0 
6 18.1 
 
22 121.7 
7 20.4 
 
23 137.1 
8 23.0 
 
24 154.4 
9 25.9 
 
25 173.9 
10 29.2 
 
26 195.9 
11 32.9 
 
27 220.6 
12 37.0 
 
28 248.5 
13 41.7 
 
29 279.9 
14 47.0 
 
30 315.3 
15 52.9 
 
31 355.1 
16 Middle 
response 
59.6 
 32 High 
response 
400.0 
 
5.1.10 In-position range 
Parameter 
Initial 
value 
Unit 
Setting 
range 
Control mode 
No. Symbol 
Name 
Position Speed Torque
PA10 INP In-position 
range 
100  pulse 
0 to 
65535 
(Note) 
 
 
 
Note. For the software version C0 or older servo amplifiers, the setting range is 0 to 10,000. 
 
Set the range, where In-position (INP) is output, in the command pulse unit before calculation of the electronic 
gear. With the setting of parameter No.PC24, the range can be changed to the encoder output pulse unit. 
Servo motor droop pulse
In-position range [pulse]
Command pulse
Command pulse
Droop pulse
In-position (INP)
ON
OFF