Korg D3200 ユーザーズマニュアル

ページ / 200
168
Various messages
The message dialog box will disappear when you click the 
OK button (or press the panel YES key).
Auto-Punch is not available in MTC Slave/Master mode.
Auto-punch recording cannot be performed if the MIDI 
Sync
 setting is set to MTC Slave or MTC Master.
Cannot have more than 100 Songs.
You cannot exceed maximum of 100 songs on one song 
drive.
→ Delete unneeded songs. Be sure to back up any data you 
wish to save before deleting it from the hard drive.
Check Sum Error occurred.
The system update has failed.
→ Try the update procedure once again from the 
beginning. If this message still appears, please contact 
your Korg distributor.
Clock source changed to internal because S/P DIF Error 
occurred.
Because the S/P DIF clock could not be detected 
correctly, the Word Clock setting Clock Source has been 
switched to Internal.
→ Make sure that the signal is being output correctly from 
the external device.
→ Make sure that the D3200 is correctly connected with the 
external device.
→ Make sure that the optical digital cable is not faulty.
Clock source changed to internal because the sampling 
frequencies do not match.
Because the external sampling frequency does not match 
the sampling frequency of the current song, the Word 
Clock
 setting Clock Source has been switched to 
Internal
.
Completed.
The operation has been completed successfully.
Continuous recording time limit exceeded.
The maximum continuous recording time is 12 hours. It 
is not possible to continuously record for longer than 
this.
Directory Path is too long.
Access is not possible because the directory path is too 
long.
→ The D3200 cannot access a path that is longer than 64 
characters. Do not create a directory path longer than 64 
characters.
Disc is not CD-RW.
The disc currently in the drive is not a CD-RW.
→ Insert a CD-RW disc.
Disk too busy.
This message will appear if repeated punch-in/out 
recording or track editing operations have fragmented 
the data on the disk, slowing down access to the hard 
drive.
→ In the TRACK“EditTrk” tab page, execute the 
“OptimizeTrk”
 operation. If this error message still 
appears even after you execute “OptimizeTrk,” go to the 
SYSTEM/MIDI
“DiskUtility” tab page and execute 
“CheckDrive.”
If “Disk too busy.” appears during playback, execute “Check 
Drive” 
with “Current Song” selected. If the message appears 
during recording, execute “Check Drive” with “Current Parti-
tion”
 selected.
In some cases, ultra-low frequencies played back in the studio may 
cause “Disk too busy.” messages to appear. In this case, elimi-
nate the problem by relocating the D3200 before you execute the 
Check Drive operation.
If the Song Type is 48 kHz/24-bit and you record multiple tracks 
(four or more tracks) simultaneously, there is a increased possibil-
ity that the state of the hard disk recording area (i.e., fragmenta-
tion) will cause the “Disk too busy.” message to appear. We 
recommend that you always execute “OptimizeTrk” (
ter recording or editing multiple tracks simultaneously in a 48 
kHz/24-bit song.
Drive Error occurred.
An error has occurred while accessing the drive.
→ If this message appears while you are working on a song 
drive, execute “Check Drive.” If the message still 
appears after executing this, format the drive.
→ If this message appears while you are working on the PC 
drive, format the PC drive.
→ If this message appears while you are working on the 
CD drive, use a different disc. If the message still 
appears, it is possible that the CD-R/RW drive has 
malfunctioned. Please contact your Korg distributor.
Exceeds drive capacity.
There is not enough free space on the drive.
→ If this message appears while you are working on a song 
drive, you can either delete the Undo data or delete 
unneeded songs. Alternatively, you can use a different 
song drive.
→ If this message appears while you are working on the PC 
drive, delete unneeded files or folders.
Exp/Cmp ratio is out of range.
The expansion/compression ratio used in the 
“ExpCmpTrk”
 track edit operation is beyond the 
allowable range. The maximum expansion is double, and 
the maximum compression is half. Change the settings 
of the TO and END locations. 
Failed to receive MIDI data.
Reception of MIDI data has failed.
Failed to write CD.
Writing to the CD-R/RW disc has failed.
→ Refer to the “Troubleshooting” section on CD-R/RW.
Failed to write System.
System updating has failed.
→ It is possible that the D3200 has malfunctioned. Please 
contact your Korg distributor.
File List data error.
There is an error in the audio data, and the song cannot 
be selected or saved.
→ Format the affected song drive.
Frame Rate does not match.
The frame rate of the incoming time code does not match 
the frame rate of the current song.
Illegal Range. In = Out or Out < In.
The operation cannot be executed because there is a 
problem with the IN and OUT locations specified for 
track editing or loop playback.