HE420A STEAM POWER HUMIDIFIER
69-1108—2
6
a. If set up correctly, the humidifier will begin oper-
ating. In “Test” mode, the humidistat will operate 
for approximately one minute. 
b. If the humidifier does not activate properly in 
“Test” mode, refer to Appendix A.
4. Set the humidistat. Refer to Humidistat Operating 
Instructions for detailed instruction on initial settings.
a. If home is occupied, set the knob to “5”, or for 
manual operation, set the knob to 35%.
b. If home is vacant, turn the knob to counterclock-
wise to “Off.”
INSTALL THE SAFETY CONTROL 
SHUTOFF
Refer to the manual “Wiring Instructions for High-Capacity 
Steam Humidifiers” (page 11) for complete instruction on 
installing the Safety Control Shutoff.
CHECK THE HUMIDIFIER 
OPERATION
After installation is complete, use the following steps to 
check the humidifier operation:
1. Turn on the humidifier water supply.
2. Be sure the humidifier has power and then plug in 
the humidifier.
3. Turn the Humidity Control to the Test position.
NOTE: If relative humidity is above 45% in the home, or 
the outdoor temperature is above 50°F, a jumper 
may need to be placed across the humidistat’s 
OUT terminals to perform this checkout.
4. Check that the furnace blower comes on to circulate 
the moist air. The blower may take as long as fifteen 
minutes to start.
5. Refer to the Humidity Control owner’s manual for 
operation.