Справочник Пользователя для Hunter Fan Type T Models

Скачать
Страница из 13
7
42747-01 • 09/21/07 • Hunter Fan Company
All wiring must be in accordance with national and local electrical 
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a 
qualified electrician.
Wall switches are not included. Select an acceptable general-use switch 
in accordance with national and local electrical codes.
4-1.  Make sure the power to the outlet box and associated wall switch 
location is still OFF.
4-2.   To connect the wires, hold the bare metal leads together and 
place a wire connector over them, then twist the wire connector 
clockwise until tight.
4-3.  Connect the bare or green ground wired (grounded) from the 
ceiling to the green ground wire (grounded) from the ceiling plate 
and the green ground wire from the fan.
4-4.  Connect the white wire (ungrounded) from the ceiling to the 
white wired (ungrounded) from the fan.
4-5.  Connect the remaining wires as follows:
   
Single Switch Wiring: 
   •  The black wire from the ceiling to the black and the black/
white wire from the fan. 
    Dual Switch Wiring: 
   •  The black wire from the ceiling to the black wire from the fan.
   •  The black/white wire from the fan to the wire for the wall
switch.
 
 CAUTION:  Be sure no bare wire or wire strands are visible after 
making connections.
4-6
  Turn the splices upward and push them carefully back through the 
ceiling plate into the outlet box.
4-7   Spread the wires apart, with the grounded wires on one side of 
the outlet box and the ungrounded wires on the other side of the 
outlet box.
4 • Wiring the Fan
Wire 
connector
Step 4-3
Step 4-4