36  
 Chapter 2  Getting Started 
DMC-2X00  
AP ,50000 
Wait until position B=50000 
SP ,10000 
Change speed of B 
EN End 
program 
To start the program, command: 
XQ #B 
Execute Program #B 
Control Variables 
Objective:  To show how control variables may be utilized.  
Instruction Interpretation 
#A;DP0 
Label; Define current position as zero 
PR 4000 
Initial position 
SP 2000 
Set speed 
BGA Move 
AMA 
Wait until move is complete 
WT 500 
Wait 500 ms 
#B  
V1 = _TPA 
Determine distance to zero 
PR -V1/2 
Command A move 1/2 the distance 
BGA 
Start A motion 
AMA 
After A moved 
WT 500 
Wait 500 ms 
V1= 
Report the value of V1 
JP #C, V1=0 
Exit if position=0 
JP #B 
Repeat otherwise 
#C Label 
#C 
EN 
End of Program 
To start the program, command 
XQ #A 
Execute Program #A 
This program moves A to an initial position of 1000 and returns it to zero on increments of half the 
distance.  Note, _TPA is an internal variable which returns the value of the A position.  Internal 
variables may be created by preceding a DMC-2x00 instruction with an underscore, _. 
Linear Interpolation 
Objective:  Move A,B,C motors distance of 7000,3000,6000, respectively, along linear trajectory.  
Namely, motors start and stop together.