Quattro DC Motor A6 Submenu 
 
Motor Parameters A6 submenu 
Parameter Description 
Units 
Default
Range 
Hidden
Item 
Run 
lock
out 
MOTOR ID 
(Motor Identification)
 
 This parameter 
allows for the selection of specific sets of 
motor parameters.  This is yet to be 
determined for DC machines.
 
- - 
N Y 
RATED MOTOR 
CURR 
(Rated Armature Amps)  Motor armature 
amps.  Note: value should be obtained 
from the motor nameplate. 
amps 
0.0 
1.0 – 400.0 
N Y 
ARMATURE VOLTS 
(Rated Armature Voltage) 
 
Rated motor 
armature circuit voltage.  Note: value 
should be obtained from the motor 
nameplate. 
amps 
55 – 600 
N N 
FULL FLD AMPS 
(Full field Amps)  This parameter sets 
motor field amps at low speed.  Note: 
value should be obtained from the motor 
nameplate. 
amps 
0.0 
1.0 – 40.0 
N N 
WEAK FLD AMPS 
(Weak field Amps)  This parameter sets 
the motor field amps at contract.  Adjust 
as necessary to obtain rated armature 
volts at contract speed at full load up.  
May be the same as or lower than Full 
field Amps for motor field weakening.  
Motor field current will automatically 
begin to weaken when motor speed is 
Contract Speed x Weak Field/Full Field 
and follow a profile for constant CEMF. 
amps 
0.0 
1.0 – 40.0 
N N 
STNDBY FIELD  
(Standby field Amps) 
 
 Motor field current 
during drive standby conditions.  Motor 
current will automatically drop to this level 
when idle after STNDBY FIELD TIME has 
expired. 
amps 
0.0 
0.0 – 40.0 
N N 
FLUX CNFRM LEVEL 
(Flux Confirm Level) 
 
 Determines the 
minimum motor field current necessary 
before drive is allowed to start.  Arranged 
as a percent of Full Field ampere setting.  
This ensures that pre-torque current to 
motor will produce adequate torque when 
the elevator Brake is released.  A lower 
setting will allow the drive to come alive 
earlier in the start cycle to help prevent 
unnecessary starting delays.  Units in 
percent of full field. 
0.0 
25.0 – 99.0 
N N 
ARMATURE IR 
DROP 
(Armature IR Drop) Adjusts motor 
armature current regulator for expected 
current x resistance voltage drop of motor 
armature circuit at rated current.  Includes 
motor armature, inter-poles and wiring 
resistance.  Enter as a percent of rated 
armature volts.  This parameter also 
affects the sensitivity of the fault, Encoder 
Fault. 
Note: This equation is only valid after an 
Auto Tune has been done.  For 
information on auto tuning the motor, see 
page 95. 
=
×


×
(A6)
DROP
 
IR
ARM
100
(A6)
  
VOLTS
ARMATURE
(A6)
 
CURR
MOTOR
  
RATED
   
(D2)
 
R
 
 ARM
MEAS
 
AUTO
 
0.0 
0.0 – 25.0 
N N 