Siemens D410 Benutzerhandbuch

Seite von 150
 
Commissioning (software) 
 
4.6 Using drive-related I/Os by SIMOTION 
D410 
Commissioning Manual, 08/2008 Edition 
101
 
Table 4-5 
Logical hardware address and the bit number (high-speed outputs for cam outputs / 
DOs) 
Logical hardware address and bit number 
Output on the D410 
Start address message frame 39x +3, bit 0 
DO 8 
Start address message frame 39x +3, bit 1 
DO 9 
Start address message frame 39x +3, bit 2 
DO 10 
Start address message frame 39x +3, bit 3 
DO 11 
For information about message frame configuring, see Use of message frame 
39x (Page 87). 
4.6.7 
Using probe inputs on D410 
Configuration of probe inputs 
Measuring inputs are used for fast, accurate measurement of actual positions. This is 
achieved with hardware support (for example, the measuring input on the assigned drive 
unit). Digital inputs for standard peripherals, e.g. distributed SIMATIC ET 200 peripheral 
system, cannot generally be used as probe inputs.  
For SIMOTION, the TO probe input technology object controls the probe input functionality. 
SIMOTION differentiates between two classes of the probe inputs; these classes have 
different properties that are configured differently. 
Local and global measuring inputs 
Depending on the used hardware platform, the following local and global measuring inputs 
are available for the measuring tasks:  
●  Local measuring inputs are axis-related and implemented in the SINAMICS drive. The 
actual position value is measured. 
●  Global measuring inputs can be freely assigned to the axes and add an internal 
timestamp to the measurement result for more precise determination of the axis positions.