Siemens D410 Benutzerhandbuch

Seite von 150
 
D410 
Commissioning Manual, 08/2008 Edition 
121
 
Maintenance and service 
5
5.1 
Replacing modules 
5.1.1 
Removing and replacing the SIMOTION D410 
Overview 
You must replace the entire SIMOTION D410 module. 
 
WARNING 
 
Always shut down the load power supply before you replace the SIMOTION D410 module. 
You shut down power using the On/Off switch of the PS power supply module, for example.
Note that power modules with FSB performance rating or higher still carry a residual 
intermediate voltage after shutdown. Wait 10 minutes before you remove any screws. 
 
You can replace a SIMOTION D410 DP with a SIMOTION D410 PN module and vice versa. 
Replace the device in HW Config 
Replacing a SIMOTION D410 DP with a SIMOTION D410 PN module and vice versa 
 
 
Note 
The following procedure describes how you replace a SIMOTION D410 DP with a 
SIMOTION D410 PN of the same firmware version (and vice versa). The procedure for 
performing a software and firmware upgrade is described in Section Performing a software 
 
Proceed as follows:  
1.  Double-click the SIMOTION D410 to be replaced in the Project Navigator of SIMOTION 
SCOUT. HW Config opens.  
2.  In the hardware catalog, open the appropriate folder structure: 
e.g. Drive Based\SIMOTION D410\6AU1 410-0AB0-0AA0