Siemens D410 Benutzerhandbuch

Seite von 150
Maintenance and service 
 
5.1 Replacing modules 
 
D410 
122
 
Commissioning Manual, 08/2008 Edition 
 
 
 
Note 
DO NOT delete the module in Slot 2 when replacing it! 
 
Figure 5-1 
HW Config module replacement 
3.  "Drag-and-drop" the new module to the upper field of the card rack and confirm the dialog 
shown with "Yes". 
The module is replaced. 
4.  Save and compile the hardware configuration in order to activate the changes. 
5.  Close HW Config. 
The configuration data for your SIMOTION device is immediately activated in the 
SIMOTION SCOUT project and the entire project saved. This includes activation of all 
changes made to the project, for example, to the axis configuration. 
6.  Select "SINAMICS Integrated" in the Project Navigator. 
7.  Open the context menu and click "Target device > Device version". A window opens in 
which you can change the appropriate version. 
8.  Select the version of the replaced D410.