Quantum DLT-S4 Anleitung Für Quick Setup

Seite von 42
 
 2U Rackmount Quick Start Guide
2
Connecting the Interface and Power 
Cables
0
Shut down and turn off the selected host server. Turn 
off all attached accessory devices, such as printers and 
other SCSI devices.
Connect the interface and power cables to the back of 
the 2U Rackmount, following the instructions below for 
the type of interface you are using. 
SCSI (SDLT 320, SDLT 600, DLT-S4, LTO-3) (see 
figure 2
)
a) Connect one end of the SCSI cable to one of the 
SCSI connectors on the back of the 
2U Rackmount. Connect the other end of the 
SCSI cable to the host.
b) Connect the SCSI terminator to the adjacent 
SCSI connector on the back of the 2U 
Rackmount.
c) Each SCSI device must have its own unique SCSI 
ID. Change SCSI ID(s) if necessary. 
Note: Any time you change the SCSI ID, you 
must turn the drive power off and then back on 
using the power button on the front of the 2U 
Rackmount.
d) Connect the power cable.  
Fibre Channel (SDLT 600, DLT-S4) (see 
figure 3
)
a) Remove the protective cap(s) from the Fibre 
Channel port on the back of the 2U Rackmount. 
b) Remove the protective covers from the ends of 
the Fibre Channel cable. 
c) Connect one end of the Fibre Channel cable to 
the Fibre Channel port on the back of the 
2U Rackmount. Connect the other end of the 
Fibre Channel cable to the host.
d) Connect the power cable.
W
ARNING
: For maximum stability, the equipment rack 
should be securely bolted to the floor per the rack 
manufacturer’s recommendations.
After installing components in the equipment rack, 
do not pull out more than one component on its 
slide rails at a time. If the equipment rack is not 
securely bolted to the floor, the weight of more than 
one extended component could cause the 
equipment rack to become unstable, tip over, and 
cause damage, serious bodily injury, or death.
N
OTE
: Be sure to connect the cables on the same 
side of the 2U Rackmount as the tape drive(s) 
you will be using. 
Figure 2  SCSI Connections   
Figure 3  Fibre Channel 
Connections 
Plug in the power cable to the nearest properly 
grounded power outlet.
Turn on the 2U Rackmount by pressing and holding the 
power button on the front panel for one second. The  
green power LED should illuminate. See 
Figure 4  Power Button and Fan  
LED 
 
  
Turn on any other devices you turned off earlier.
Turn on the host server.
C
AUTION
: An illuminated fan LED (the left LED on the 
front panel) indicates a fan failure (see 
Confirm that this has not occurred. If the fan LED is 
illuminated, contact Quantum (
Power cable
SCSI 
terminator
SCSI 
cable
Fibre 
Channel 
cable
Power cable
Fan failure LED
Power button
Power LED