Lennox gas stove Benutzerhandbuch

Seite von 30
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
p
ipe
 C
learanCes
All  installations  using  a  vertical  termination  cap  must
maintain one inch clearance between the direct vent pipe
and combustibles. For horizontal runs of pipe, one inch of
clearance to combustibles on the sides and bottom, and
two inches on the top of the pipe is required. See page 14
for allowable pipe configurations.
5-5/8”
(14mm)
10”
(54mm)
8-7/8”
(5mm)
Leg on Combustible
Carpet
1-1/” Maximum
C
learanCes
 
to
 C
ombustibles
Minimum  clearances  to  combustible  materials  in  inches
(millimeters):  
Parallel Installation
Corner Installation
a
lCove
 
dimensions
The minimum width between the alcove side walls is 51”
1295mm). The minimum height of the alcove is 46” (1168mm)
and the maximum depth is 35” (889mm).
f
loor
 p
roteCtion
A non-combustible hearth pad is not required. This stove
may be installed on a combustible surface as long as the
combustible material (such as carpeting) does not extend
1-1/2”  (38mm)  vertically  above  the  bottom  of  the  base.
Also, the floor beneath the stove must be stable, level, hard,
and strong enough to support the stove without a tipping
hazard.
     51” 
(195mm)
    Min.
     5” 
(889mm)
    Max.
4” 
(118mm)
Min.
Alcove Dimensions
Figure 4
Figure 5
Figure 
” (51mm)
15” (81mm)
Min.
4-1/4” 
(1mm)
Min.
90°
10”
(54mm)
Figure 7