Vogelzang International Stove TR008 Benutzerhandbuch

Seite von 22
TR008 / 050207.2 
DURANGO™ / 
Page 
ChImNEY CONNECTIONS
The stove must be connected to either a ma-
sonry  or  manufactured  metal  chimney  built  and 
tested to the specifications listed on the previous 
pages.
Chimneys perform two functions:
1). As a means of exhausting smoke and flue 
gases which are the  result of fuel combustion. 
2). The chimney provides “draft” which allows 
oxygen  to  be  continuously  introduced  into  the  
appliance, so that proper combustion is possible. 
This stove relies on natural draft to operate.
NOTICE: Always provide a source of fresh air 
into the room where the stove is located. Failure 
to do so may result in air starvation of other fuel 
burning appliances and the possible development 
of hazardous conditions, fire or death. 
Your stove itself does not create draft. Draft is 
provided by the chimney. To achieve proper draft 
your chimney must meet the three minimum height 
requirements detailed in figures 9–11. A minimum 
of 0.05 w.c. (measured in water column) is required 
for proper drafting to prevent back puffing, smoke 
spillage, and to maximize performance. (Gauges to 
measure draft are readily available at stove stores 
and are economical to rent or purchase.)
Factors  such  as  wind,  barometric  pressure, 
trees, terrain and chimney temperature can have 
an adverse effect on the draft. The manufacturer 
cannot  be  held  responsible  for  external  factors 
leading to less than optimal drafting.
Should  you  have  a  problem  with  inadequate 
draft, you should contact a licensed heating and 
cooling  contractor  for  assistance  in  solving  the 
problem.
IMPORTANT Installation Points
1.  Size chimney flue to stove collar. This stove 
requires a 6” diameter flue.
2.  Never connect this unit to a chimney serv-
ing another appliance.
3.  The  chimney  must  meet  all  minimum 
height requirements.
4.  Never use a chimney to ventilate a cellar 
or basement.
5.  Contact  your  local  building  authority  
for  approved  methods  of  installation  and  any  
necessary permits and/or inspections.
MasonRy chIMney
Before  using  an  existing  masonry  chimney, 
clean the chimney, inspect the flue liner and make 
any repairs needed to be sure it is safe to use. Make 
repairs  before  attaching  the  stove.  The  connec-
Fig. 9 - Chimney Construction Through Attic Space
CHImNEY
FLUE
5/8" TILE
CHImNEY
LINER
mASONRY
CHImNEY
THImBLE
COLLAR
6˝ ROUND
24 ga. BLACk
CONNECTOR
STOVEPIPE
8˝ mIN.
LINER
BELOw
ENTRY
HOLE
tor stove pipe and fittings you will need to con-
nect directly to a masonry chimney are shown in  
figure 8. 
If  the  connector  stove  pipe  must  go  through 
a  combustible  wall  before  entering  the  masonry 
chimney,  consult  a  qualified  mason  or  chimney 
dealer.  The  installation  must  conform  to  local 
building and fire codes and latest edition of NFPA 
Fig. 8 -  Masonry Chimney Connection
211.
If there is a cleanout opening in the base of the 
chimney, close it tightly.