Telus Modem IR1200 Benutzerhandbuch

Seite von 54
 
iR1200 Modem 
27 
 
10.  The Phone Number to Dial window opens. Enter s=2 and click Next
11.  The Internet Account Information window opens. You can leave the username and password fields blank. Remove 
the check marks next to the three options.  
 
Use this account name and password when anyone connects – unchecked 
 
Make this the default Internet connection – unchecked 
 
Turn on Internet Connection Firewall - unchecked 
12.  The Completing the New Connection Wizard screen opens. Click to select the option “Add a Short to my 
desktop…” and click Next
13.  The iDEN
 Modem Connection window opens. Click the Properties button. 
14.  The iDEN
 Modem Connection Properties window opens. On the General tab, verify that the Standard 19200 bps 
Modem is checked. All the other modems listed should be unchecked. 
15.  Click the Networking tab. Under the PPP Windows 95/98… section and click the Settings button. Verify the 
following settings: 
 
Enable LCP Extensions – unchecked 
 
Enable Software Compression Options – unchecked 
 
Enable the Negotiate Multi-line for single... option – checked 
16.  Click OK to continue. 
17.  Click Cancel to close the Connection window. 
Modem Profiles and Settings 
This section describes how to use AT commands to setup parameters and configure the iR1200 modem for Normal mode 
usage. A HyperTerminal session must be setup for you to enter AT commands.  
Opening a HyperTerminal Session 
The following steps describe how to start a HyperTerminal Session: 
1. 
Windows 2000/XP/Windows 98
StartàProgramsàAccessoriesàCommunicationsàHyperTerminal. 
2. 
Windows NT: 
StartàProgramsàAccessoriesàHyperTerminalàHyperTerminal 
3. 
The HyperTerminal window will open. You are now ready to issue AT commands to the Modem. 
Configuring with AT Commands 
Changing Factory Default Image 
The iR1200 modem’s factory default image 2 is configured to start up with packet data. If you are using circuit switched data, 
we recommend that you perform the following steps. 
Step 1 – Backup image 2 (default) to image 1 
AT Command 
Save User Default profile 2 to profile 1 
Command Syntax 
AT&W1 
Expected Return Code(s) 
OK 
 
Step 2 – Change default call setting (packet data) to circuit switched  
AT Command 
Change Call Setting Parameter