Telus Modem IR1200 Benutzerhandbuch

Seite von 54
 
TELUS Mobility™ 
28 
 
  
 
 
Command Syntax 
ATZ0 
Expected Return Code(s) 
OK 
 
Step 3 – Save new setting as default profile. 
AT Command 
Save User Default Configuration 
Command Syntax 
AT&W2 
Expected Return Code(s) 
OK 
Restore Factory Defaults [AT&F] 
To ensure a clean configuration process, you should restore the current values to their factory default values by applying the 
following. 
AT Command 
Restore Factory-Default Configuration 
Command Syntax 
AT&F 
Expected Return Code(s) 
OK 
Activate DTR Monitoring [AT&D2] 
The DCE does not monitor the DTR line of the DTE/DCE physical connection. This is the default factory setting. To activate 
DTR monitoring in the DCE, you must apply the following command. 
AT Command 
DTR Behavior 
Command Syntax 
AT&D2 
Expected Return Code(s) 
OK 
Activate DCD Management [AT&C1] 
The factory default for the modem keeps the Data Carrier Detect (DCD) line of the computer-to-modem physical connection 
active at all times. Some communication programs monitor this line to determine the status of the connection. To promote 
compatibility with these programs, enable DCD management in the modem. 
AT Command 
DCD Behavior 
Command Syntax 
AT&C1 
Expected Return Code(s) 
OK 
Select iDEN
 Packet Wireless Data [AT+WS46=24] 
The iR1200 modem supports multiple wireless data formats. Select the desired data service by applying the following command. 
AT Command 
Select WDS-side stack 
Command Syntax 
AT+WS46=24 
Expected Return Code(s) 
OK 
Select SLIP [AT+WS45=3]  or PPP [AT+WS45=4]  
By default, the modem attempts to establish a PPP connection. To specify the type of connection the modem will establish, 
apply the following command. 
AT Command 
Select computer-side stack 
Command Syntax 
AT+WS45=4 (PPP) 
AT+WS45=3 (SLIP) 
Expected Return Code(s) 
OK