Leibherr USA Refrigerators and freezers for integrated use, door-on-door HRB 1110 HF 851 Benutzerhandbuch

Seite von 14
5 Water supply*
WARNING
Electrical Shock Hazard!
u
Do not make the water connection while the appliance is
connected to an electrical outlet.
u
Disconnect the water supply before connecting the water
lines for the IceMaker.
u
The connection to the water supply may only be made by
a trained and licensed plumber.
WARNING
Poisoning Hazard!
u
The water quality must comply with the drinking water
regulations  for  the  geographical  area  where  the
appliance is located.
u
The IceMaker is designed exclusively to make ice cubes
in quantities needed by a household and must only be
operated with water appropriate for this purpose.
Water pressure:
bar
psi
MPa
1.5 to 6 21.76 to 87.02 0,15 to 0,6
- Water must be supplied to the appliance by means of a
cold-water  pipe  that  can  withstand  the  operating
pressure and conforms to hygiene regulations.
- A shut-off valve must be provided between the hose line
and  the  domestic  water  supply  to  turn  off  the  water
supply, if necessary.
- All  devices  and  fixtures  used  to  supply  water  must
comply  with  the  regulations  in  force  in  the  respective
country.
- Do  not  damage  or  bend  the  water  supply  pipe  during
installation.
- The  solenoid  valve  is  located  on  the  back  of  the
appliance at the bottom. It has a European Metric R¾
male  connection.  Do  not  use  Garden  Hose  Threaded
fittings on the solenoid valve - they will leak.
u
Open  the  shut-off  valve  of  the  water  supply
pipe  and  check  the  entire  water  system  to
ensure there are no leaks.
Before initial operation:
u
Have a competent fitter bleed all air from the
water supply pipe. IceMaker will not function if
there is air in the water supply line.
NOTICE
Malfunction of the water intake!
If  the  water  intake  is  shut  off  during  operation  but  the
IceMaker remains in operation, the water intake pipe may
ice up.
u
Switch off the IceMaker if the water supply is interrupted
(e.g. holiday).
6 Installation
All fasteners are supplied with the appliance.
Fig. 10 
Make sure you have the following tools on hand:
q
Cordless screwdriver Torx® 15, 20, 25
q
Hex wrench 13
q
Phillips screwdriver
The floor and side walls of the unit must be at right angles
to one another. Make the unit level using a spirit level and
set  square.  If  necessary,  level  up  by  placing  something
underneath.
The  appliance  can  also  be  built  into  a  normal  kitchen
cabinet. In this case detach the fittings of the unit door and
the recess. They are no longer needed as the unit door is
fitted to the appliance door.
Note
u
Before  assembling  the  unit  door,  make  sure  that  the
permitted weight for the unit doors is not exceeded.
u
Otherwise  damage  to  the  hinges  and  malfunctions
arising from this cannot be ruled out.
Model
Maximum weight of
unit door
IKB 3650
39.68 lbs (18 kg)
IGN 2566
44.09 lbs (20 kg)
Water supply
9