Important Installation Information: 
Attach anti-tip bracket to a solid wood cabinet having a
minimum wall thickness of 3/4” (19mm). The thickness
of the wall or floor may require use of longer screws,
available at your local hardware store.
Use appropriate anchors when fastening the mounting
bracket to any material other than hard-wood or metal.
In all cases, at least (2) of the bracket mounting screws
must firmly fasten the anti-tip bracket to the floor, and
(2) of the mounting screws (or drywall anchors) must
firmly fasten the anti-tip bracket to the rear wall (see
Figure 11 and Figure 12).
Mounting the Anti-Tip Bracket
1.
Prepare holes at fastener locations as identified below:
For walls, wall studs, or floors composed of solid 
wood or metal, drill 1/8” (3.17mm) pilot holes.
For walls or floors composed of drywall, sheet-rock 
or other soft materials, drill 3/16” (4.76mm) holes to 
a minimum depth of 1
3
/
4
” (44mm), then tap plastic 
anchors into each of the holes using a hammer.
For walls or floors composed of concrete or 
concrete block, drill 3/16” (4.76mm) holes to a 
minimum depth of 1
3
/
4
” (44mm), then tap concrete 
anchors into each of the holes using a hammer.
For walls or floors having ceramic tile covering, drill 
3/16” (4.76mm) holes through the tile only, then 
drill into the material behind the tile as indicated 
immediately above.
2.
Place bracket on floor near the center of where the unit 
is to be finally located (shown in Figure 11).
If the range is moved to a new location, the Anti-Tip 
Device must be reinstalled.
3.
Secure bracket into the wall stud and to the floor using 
the screws provided.
4.
Later, when the unit is installed, the adjustable legs will 
allow the cast base to slide under the bracket hook, 
stabilizing the unit.
 F
IGURE 
11: A
NTI
-
TIP 
B
RACKET 
M
OUNTING 
L
OCATION
3”
(76mm)
Gas Supply
Zone
Electric Supply
Zone
 F
IGURE 
12: A
NTI
-
TIP 
B
RACKET
With the range in its final installed 
location, the hook of the anti-tip 
bracket will overhang the back of 
the range’s cast-aluminum base, in 
a position just above the cast base. 
Use (2) of the mounting 
screws through these two 
holes to fasten the anti-tip 
bracket to the floor.
Use (2) mounting screws 
(or drywall anchors, as 
appropriate) through two 
of these holes to fasten 
the anti-tip bracket to the 
rear wall.