Step 6: Gas Requirements and 
Hookup
Verify the type of gas being used at the installation site. As 
shipped from the factory, units are configured for use with 
only natural gas or propane (LP) gas. Make certain the 
range matches the type of gas available at this location. 
These ranges are NOT convertible between different types 
of gas.
For installation of the appliance at high altitude, please 
consult your local gas company for their recommendation 
of the correct orifice sizes and any other necessary 
adjustments that will provide proper gas combustion at 
specified altitudes.
Hook Up
The gas supply connections shall be made by a competent 
technician and in accordance with local codes or 
ordinances. In the absence of a local code, the installation 
must conform to the National Fuel Gas Code ANSI Z223.1/
NFPA54- current issue.
A manual gas shut-off valve must be installed external to 
the appliance, in a location accessible from the front, for 
the purpose of shutting off the gas supply. The supply line 
must not interfere with the back of the unit. Make sure the 
gas supply is turned off at the manual shut-off valve before 
connecting the appliance.
The range is supplied with its own pressure regulator that 
has been permanently mounted inside the range.
Use 3/4” (19mm) flex line to connect between the gas 
supply and the appliance inlet pipe, which exits at the 
rear, lower right of the appliance. The appliance pipe 
connection has a 3/4” (19mm) NPT external thread and 
a 1/2” (13mm) NPT internal thread (see Figure 13). 
Use caution to avoid crimping the 3/4” (19mm) flex line 
when making bends. Suggested length of the flex line 
is 48” (1219mm); however, check local codes for 
requirements before installation. 
Always use pipe sealing compound or Teflon
®
 tape on 
the pipe threads, and be careful not to apply excessive 
force when tightening the fittings.
Leak testing of the appliance shall be in accordance 
with the following instructions.
NATURAL GAS REQUIREMENTS:
Inlet Connection:
3/4” (19mm) NPT external
1/2” (12.7mm) NPT internal
(Minimum 3/4” dia. flex line) 
Supply Pressure:
6" min. to 14" max. water column.
(14.9 to 34.9 mb)
Manifold Pressure:
5" water column (12.5 mb)
PROPANE GAS REQUIREMENTS:
Inlet Connection:
3/4” (19mm) NPT external
1/2” (12.7mm) NPT internal
(Minimum 3/4” dia. flex line) 
Supply Pressure:
11" min. to 14" max. water 
column. (27.4 mb to 34.9 mb)
Manifold Pressure:
10" water column (24.9 mb)
CAUTION: 
When connecting unit to propane gas, make certain the 
propane gas tank is equipped with its own high pressure 
regulator in addition to the pressure regulator supplied 
with the appliance. The pressure of the gas supplied to 
the appliance regulator must not exceed 14" water col-
umn (34.9 mb).
CAUTION: 
Do not remove the back cover of the range. It is for an 
authorized servicer access only.
 F
IGURE 
13:  M
ANIFOLD 
G
AS 
L
INE 
C
ONNECTION
Gas Line Connection