Turn on gas and check supply line connections for 
leaks using a soap and water solution. Bubbles forming 
indicate a gas leak. Repair all leaks immediately after 
finding them. 
The appliance and its individual shut off valve must be dis-
connected from the gas supply piping system during any 
pressure testing of the system at test pressures in excess 
of 1/2 psig (3.5kPa.). 
When checking the manifold gas pressure, the inlet 
pressure to the regulator should be at least 6.0" W.C. (14.9 
mb) for natural gas or 11.0" W.C. (27.4 mb) for propane. 
Step 7: Electrical Requirements, Connection & Grounding
Before installing, turn power OFF at the service panel. 
Lock service panel to prevent power from being turned 
on accidentally.
A neutral supply wire must be provided from the power 
source (breaker panel) because critical range 
components, including the surface burner spark 
reignition modules, require 120 VAC to operate safely 
and properly. 
If the correct power supply circuit is not provided, it is 
the responsibility and obligation of the installer and 
user to have proper power supply connected. This 
must be accomplished in accordance with all 
applicable local codes and ordinances by a qualified 
electrician. In the absence of local codes and 
ordinances, the power supply connection shall be in 
accordance with the National Electrical Code. 
Observe all governing codes and ordinances when 
grounding. In the absence of these codes or 
ordinances observe National Electrical Code ANSI/
NFPA No. 70 current issue. 
Electric wiring diagrams and schematics are attached 
behind the door trim of the range, for access by a 
qualified service technician (see Figure 6 on page 9). 
IMPORTANT:
For all gas ranges with electric griddle, dedicated 20 AMP 
service is required for proper operation. Before you plug in 
an electrical cord, be sure all controls are in the OFF 
position. 
For appliances equipped with a cord and plug, do not cut or 
remove the ground prong. It must be plugged into a 
matching grounding type receptacle to avoid electrical 
shock. If there is any doubt as to whether the wall 
receptacle is properly grounded, the customer should have 
it checked by a qualified electrician. 
Installer — Show the owner the location of the circuit 
breaker. Mark it for easy reference. 
CAUTION: 
The appliance must be isolated from the gas supply 
piping system by closing its individual manual shut-off 
valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 1/2 
psig (3.5kPa.). 
WARNING: 
Do not use a flame of any kind to check for gas leaks.
Chart B: Electrical Supply Circuit Requirements
MODEL
TYPE
VOLTAGE
CURRENT
RATING
FREQUENCY 
PHASE 
36"
120 VAC
15 Amps
60 Hz.
Single
36" with Griddle
120 VAC
20 Amps
60 Hz.
Single
48" with Griddle
120 VAC
20 Amps
60 Hz.
Single
WARNING: 
An improper 120 VAC power supply will cause 
malfunction, damage to this appliance, and possibly 
create a condition of shock hazard.