Important Installation Information
Gas Type Verification 
Verify the type of gas supplied to the location. Ensure that 
the appliance is connected to the type of gas for which it is 
certified. All ranges are certified for use with natural gas or 
propane (LP) gas. Make certain the range matches the gas 
type available.
 
Hookup” on page 14 before proceeding with the installation.
Gas Supply:
Natural Gas — 6 inch water column. (14.9 mb) min., 14 
inch (34.9 mb) maximum
Propane Gas — 11 inch water column. (27.4 mb) min., 14 
inch (34.9 mb) maximum
Electric Power Supply:
 
36" Models:
6 Burners – 120 VAC, 60 Hz., 1Ph., 15 Amp circuit
4 Burners with Griddle – 120 VAC, 60 Hz., 1Ph., 20 Amp 
circuit
48" Models:
6 Burners with Griddle – 120 VAC, 60 Hz., 1Ph., 20 Amp 
circuit
Check local building codes for the proper method of 
appliance installation. Local codes vary and it is the 
responsibility of the installer to ensure installation is in 
accordance with these codes. Installation, electrical 
connections and grounding must comply with all applicable 
codes. In the absence of local codes the appliance should 
be installed in accordance with the National Fuel Gas Code 
ANSI Z223.1/ NFPA 54 current issue and National 
Electrical Code ANSI/NFPA 70 -current issue. In Canada, 
installation must be in accordance with the CAN 1-B149.1 
and .2 – Installation Codes for Gas Burning Appliances 
and/or local codes. 
IMPORTANT:
 
When installing against a combustible surface, a High Shelf 
or Low Backguard is required. A THERMADOR
®
 High 
Shelf or Low Backguard must be purchased separately. 
See Step 8 on page 16 for backguard, kits and installation 
information. 
When using the Flush Island Trim, THERMADOR 
recommends a minimum 12” (305 mm) rear clearance to a 
combustible surface (see Figure 1, Cabinet Clearances). 
Clearances from non-combustible materials are not part of 
the ANSI Z21.1 scope and are not certified by 
CSA. Clearances of less than 12” (305 mm) must be 
approved by the local codes and/or by the local authority 
having jurisdiction.
Refer to “Backguard Kit Model Numbers” on page 21, for 
the correct backguard models that are designed for this 
range. After selecting the correct backguard, the range 
must be installed properly, using the minimum clearances 
to combustible surfaces specified in See “Step 2: Cabinet 
Preparation” on page 4.
 
WARNING: 
To avoid possible burn or fire hazard, a backguard 
designed specifically for this range must be installed 
whenever the range is used.
CAUTION: 
When connecting the unit to propane gas, make certain 
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator 
supplied with the range. The maximum gas pressure to 
this appliance must not exceed 14.0” water column (34.9 
mb) from the propane gas tank to the pressure regulator. 
CAUTION: 
This unit is designed as a cooking appliance. Based on 
safety considerations, never use it for warming or 
heating a room.
CAUTION: 
To eliminate risk of burns or fire caused by reaching over 
heated surface units, cabinet storage located above the 