Thermador PRG366JG Installationsanweisungen

Seite von 90
English 3
It is strongly recommended that this appliance be installed 
in conjunction with a suitable overhead vent hood (see 
“Step 1: Ventilation Requirements” on page 3). Due to the 
high heat capability of this unit, particular attention should 
be paid to the hood and duct work installation to assure it 
meets local building codes.
This appliance has been tested in accordance with ANSI 
Z21.1, Standard for Household Cooking Appliances (USA) 
and in accordance with CAN 1.1-M81 Domestic Gas 
Ranges (Canadian).
This appliance complies with one or more of the following 
standards: 
UL 858, Standard for the Safety of Household Electric 
Ranges 
UL 923, Standard for the Safety of Microwave Cooking 
Appliances 
UL 507, Standard for the Safety of Electric Fans 
ANSI Z21.1, American National Standard for 
Household Cooking Gas Appliances 
CAN/CSA-C22.2 No. 113-10 Fans and Ventilators 
CAN/CSA-C22.2 No. 61-08 Household Cooking 
Ranges 
It is the responsibility of the owner and the installer to 
determine if additional requirements and/or standards 
apply to specific installations.
Step 1: Ventilation 
Requirements
It is strongly recommended that a suitable exhaust hood be 
installed above the range. Downdraft ventilation should not 
be used. The table below indicates the ventilation hood 
options and blower capacity guidelines that are 
recommended for use with all THERMADOR
®
 ranges.
Do not install a microwave oven/ventilator combination 
above the range as these type of units do not provide the 
proper ventilation and are not suitable for use with the 
range.
IMPORTANT
Ventilation hoods and blowers are designed for use with 
single wall ducting. However, some local building codes or 
inspectors may require double wall ducting. Consult local 
building codes and/or local agencies before starting to 
assure that hood and duct installation will meet local 
requirements. 
NOTICE:
Most range hoods contain combustible components which 
must be considered when planning the installation.
1.
Select Hood and Blower Models: 
For wall installations, the hood width must, at a 
minimum, equal the width of the range. Where space 
permits, a hood larger in width than the range may be 
desirable for improved ventilation performance. 
For island installations, the hood width should 
overhang the range by a minimum of 3" (76mm) on 
each side. 
2.
Hood Placement: 
For best smoke elimination, the lower edge of the hood 
should be installed 30" (762mm) above the range 
cooking surface. Use a 36" (914mm) minimum 
clearance if the hood contains any combustible 
materials such as a wood covering (Figure 1 on 
page 5
).
 
3.
Consider Make-Up Air: 
Due to the high volume of ventilation air, a source of 
outside replacement air is recommended. This is 
particularly important for tightly sealed and insulated 
homes. 
A qualified heating and ventilating contractor should be 
consulted. 
Tools Needed
(2) 1/2” wrenches
1/8” (3.17mm) drill bit
3/16” (4.76mm) drill bit
12” Adjustable wrench
Hand or electric drill
Tape measure
Phillips & flathead screwdrivers
Marking instrument
Level
Furniture dolly
T-20 Torx screwdriver
Protective gloves
Items Not Included
Drywall/Concrete Anchors
Pipe Compound/Tape
Rope/Twine
3/4” (19mm) Flex Line
(2) NPT Flare Adapters