Thermador PRG366JG Installationsanweisungen

Seite von 90
English 4
Step 2: Cabinet Preparation
The range is a free standing unit. If the unit is to be 
placed adjacent to cabinets, the clearances shown in 
Figure 1 on page 5 are required. The same clearances 
apply to island installations, except for the overhead 
cabinets, which must have a space wide enough to 
accept the flared island hood, as also indicated in 
Figure 1 on page 5.
The range should not be recessed into the cabinets 
beyond the edge of the front face of the oven (see 
Figure 2 on page 6).
The gas and electrical supply should be within the 
zones shown in Figure 4 on page 7.
Any openings in the wall behind the range and in the 
floor under the range must be sealed.
When installing against a combustible surface, a High 
Shelf or Low Backguard is required. A THERMADOR
®
 
High Shelf or Low Backguard must be purchased 
separately (see chart below for Model Numbers).
When using the Flush Island Trim, THERMADOR 
recommends a minimum 12” (305 mm) rear clearance 
to a combustible surface (see Figure 1, Cabinet 
Clearances
). Clearances from non-combustible 
materials are not part of the ANSI Z21.1 scope and are 
not certified by CSA. Clearances of less than 12” (305 
mm) must be approved by the local codes and/or by 
the local authority having jurisdiction.
When the range is installed against a combustible side 
wall a minimum clearance of 5” (127mm) is needed 
from the side of the range to the wall. 
Always keep appliance area clear from combustible 
materials, gasoline and other flammable vapors and 
liquids. 
Do not obstruct the flow of combustion and ventilation 
air to the unit. 
The maximum depth of overhead cabinets installed on 
either side of the hood is 13" (330mm). 
A 36” (914mm) minimum clearance is required between the 
cooking surface of the range and the bottom of an 
unprotected cabinet. A 30” (762mm) clearance can be 
used when the bottom of the wood or metal cabinet is 
protected by not less than 1/4” (6mm) of a flame retardant 
material covered with not less than No. 28 MSG sheet 
steel, 0.015” (0.38 mm) thick stainless steel, 0.024” (0.61 
mm) aluminum, or 0.020” (0.51 mm) thick copper. 
Flame retardant materials bare the following mark: 
UNDERWRITERS LABORATORIES INC. CLASSIFIED 
MINERAL AND FIBER BOARDS SURFACE BURNING 
CHARACTERISTICS 
followed by the flame spread and smoke ratings. These 
designations are shown as “FHC (FIame Spread/Smoke 
Developed).” Materials with “O” flame spread ratings are 
flame retardant. Local codes may allow other flame spread 
ratings. It is the responsibility of the installer to ensure 
installation is in accordance with these ratings.
Range 
Width
Range Top Configuration
Cubic Feet per Minute
(min requirement)
Ventilation Options
36"
4 burners with griddle
   800 (cfm)
36” or 42” Pro Wall Hood
36” Custom Insert w/ optional blower
42” or 48” Island Hood w/ optional blower
6 burners
1100 (cfm)
48"
6 burners with griddle
    1200 (cfm)
48” or 54” Pro Wall Hood
48” Custom Insert w/ optional blower
Important Notes:
It is recommended that a THERMADOR PROFESSIONAL
®
 wall or island hood or custom insert is used with 
THERMADOR PROFESSIONAL
®
 ranges. Refer to www.thermador.com for a complete selection of Professional 
Ventilation options, Blowers, and Accessories.
* For high output gas ranges (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is 
recommended. If the range has a griddle, add 200 CFM to the estimated blower capacity. Additional blower capacity may 
be required for longer duct runs.
For island applications, it is recommended to use a hood width that exceeds the width of the range by 6” (152mm), 
overlapping the range by a minimum of 3” (76mm) on each end.
CFM = “cubic feet per minute” (standard blower capacity rating).