255/460i Troubleshooting
7. Control 
backwashes or 
purges at 
excessively low or 
high rate.
a. Incorrect drain controller 
used.
b. Foreign matter affecting 
controller operation.
a. Replace with correct size 
controller. (Contact dealer.)
b. Remove drain controller and 
clean ball and seat.
Problem
Possible Cause
Solution
1. Clock does not 
display time of 
day.
a. Transformer cord 
unplugged.
b. No electric power at 
outlet.
c. Defective transformer.
d. Defective circuit board.
a. Connect power.
b. Repair outlet or use working 
outlet.
c. Replace transformer. 
(Contact dealer.)
d. Replace timer. (Contact 
dealer.)
2. Clock does not 
display correct 
time of day.
a. Outlet operated by 
switch.
b. Incorrect voltage or 
frequency (Hz).
c. Power outages.
a. Use outlet not controlled by 
switch.
b. Replace timer with one of 
correct voltage and 
frequency (Hz). (Contact 
dealer.)
c. Reset clock.
3. Time display 
continues to 
advance.
a. Defective time set switch.
a. Replace timer. (Contact 
dealer.)
4. Time display 
shows something 
other than time of 
day.
a. Electrical interference.
b. Defective circuit board.
a. Disconnect power to unit. 
Restore power and reset 
time of day display.
b. Replace timer. (Contact 
dealer.)
5. No water flow 
display when 
water is flowing.
a. Bypass valve in bypass.
b. Meter probe 
disconnected or not fully 
connected to meter 
housing.
c. Restricted meter turbine 
rotation due to foreign 
material in meter !
d. Defective meter probe.
e. Defective circuit board.
a. Shift bypass valve to not-in-
bypass position.
b. Fully insert probe into meter 
housing.
c. Remove meter housing, free 
up turbine and flush with 
clean water. Turbine should 
spin freely. If not, replace 
meter. (Contact dealer.)
d. Replace timer. (Contact 
dealer.)
e. Replace timer. (Contact 
dealer.)
Problem
Possible Cause
Solution