Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  6   TIMER  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
246  
Jul 04, 2013 
Figure 6-44.  Operation Procedure of Interval Timer/Square Wave Output Function (2/2) 
 
 Software 
Operation 
Hardware 
Status 
TAU 
stop 
To hold the TOmn pin output level 
Clears the TOmn bit to 0 after the value to  
be held is set to the port register. 
When holding the TOmn pin output level is not necessary 
Setting not required. 
 
 
The TOmn pin output level is held by port function. 
 
 
 
The TAUmEN bit of the PER0 register is cleared to 0. 
Power-off status 
All circuits are initialized and SFR of each channel is also 
initialized. 
(The TOmn bit is cleared to 0 and the TOmn pin is set to 
port mode.) 
 
Remark  m: Unit number (m = 0), n: Channel number (n = 0 to 7 (however, timer input pin (TImn), timer output pin 
(TOmn) : n = 0, 1, 3 to 7))