Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  11   A/D  CONVERTER 
R01UH0305EJ0200  Rev.2.00 
 
 
361  
Jul 04, 2013 
Figure 11-7.  Format of A/D Converter Mode Register 2 (ADM2) (2/2) 
 
Address: F0010H     After reset: 00H     R/W 
Symbol 
7 6 5 4 
<3> 
<2> 
<0> 
ADM2 ADREFP1  ADREFP0  ADREFM 
ADRCK 
AWC 
ADTYP 
 
ADRCK 
Checking the upper limit and lower limit conversion result values 
The A/D conversion end interrupt request signal (INTAD) is output when the ADLL register 
≤ the ADCR 
register 
≤ the ADUL register (AREA1). 
The A/D conversion end interrupt request signal (INTAD) is output when the ADCR register < the ADLL 
register (AREA2) or the ADUL register < the ADCR register (AREA3). 
Figure 11-8 shows the generation range of the A/D conversion end interrupt request signal (INTAD) for AREA1 to 
AREA3. 
 
AWC 
Specification of the SNOOZE mode 
Do not use the SNOOZE mode function. 
Use the SNOOZE mode function. 
When there is a hardware trigger signal in the STOP mode, the STOP mode is exited, and A/D conversion is performed 
without operating the CPU (the SNOOZE mode). 
•  The SNOOZE mode function can only be specified when the high-speed on-chip oscillator clock is selected for the 
CPU/peripheral hardware clock (f
CLK
).  If any other clock is selected, specifying this mode is prohibited. 
•  Using the SNOOZE mode function in the software trigger mode or hardware trigger no-wait mode is prohibited. 
•  Using the SNOOZE mode function in the sequential conversion mode is prohibited. 
•  When using the SNOOZE mode function, specify a hardware trigger interval of at least “shift time to SNOOZE 
mode
Note 1
 + A/D power supply stabilization wait time + A/D conversion time +2 f
CLK
 clock” 
•  Even when using SNOOZE mode, be sure to set the AWC bit to 0 in normal operation and change it to 1 just before 
shifting to STOP mode. 
Also, be sure to change the AWC bit to 0 after returning from STOP mode to normal operation. 
If the AWC bit is left set to 1, A/D conversion will not start normally in spite of the subsequent SNOOZE or normal 
operation. 
 
ADTYP 
Selection of the A/D conversion resolution 
0 12-bit 
resolution
Note 2
 
1 8-bit 
resolution 
Notes 1.  Refer to “Transition time from STOP mode to SNOOZE mode:” in 18.3.3  SNOOZE mode 
 2.  The valid resolution differs depending on the voltage conditions of AV
DD
 and AV
REFP
 
 
For details, see 29.6.1  A/D converter characteristics
 
Caution  Rewrite the value of the ADM2 register while conversion operation is stopped (ADCS = 0, ADCE = 0). 
 
Figure 11-8.  ADRCK Bit Interrupt Signal Generation Range 
 
111111111111B
000000000000B
ADCR register value
(A/D conversion result)
AREA 1
(ADLL 
≤ ADCR ≤ ADUL)
AREA 2
(ADCR < ADLL)
AREA 3
(ADUL < ADCR)
ADUL register setting
INTAD is generated
when ADRCK = 0.
INTAD is generated
when ADRCK = 1.
INTAD is generated
when ADRCK = 1.
ADLL register setting
 
 
Remark  If INTAD does not occur, the A/D conversion result is not stored in the ADCR or ADCRH register. 
<R> 
<R> 
<R>