Renesas rl78 User Manual
RL78/G1A
CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00
438
Jul 04, 2013
(1) Register setting
Figure 12-24. Example of Contents of Registers for Master Transmission of 3-Wire Serial I/O
(CSI00, CSI01, CSI10, CSI11, CSI20, CSI21) (1/2)
(a) Serial mode register mn (SMRmn)
15
14
13
12
11
10
9 8 7 6 5 4 3 2 1 0
SMRmn
CKSmn
0/1
CCSmn
0
0
0
0
0
0
STSmn
0
0
SISmn0
0
1
0
0
MDmn2
0
MDmn1
0
MDmn0
0/1
Operation clock (f
MCK
) of channel n
0: Prescaler output clock CKm0 set by the SPSm register
1: Prescaler output clock CKm1 set by the SPSm register
1: Prescaler output clock CKm1 set by the SPSm register
Interrupt source of channel n
0: Transfer end interrupt
1: Buffer empty interrupt
(b) Serial communication operation setting register mn (SCRmn)
15
14
13
12
11
10
9 8 7 6 5 4 3 2 1 0
SCRmn
TXEmn
1
RXEmn
0
DAPmn
0/1
CKPmn
0/1
0
EOCmn
0
PTCmn1
0
PTCmn0
0
DIRmn
0/1
0
SLCmn1
0
SLCmn0
0
0
1
DLSmn1
1
Note 1
DLSmn0
0/1
Selection of the data and clock
phase (For details about the
setting, see 12.3 Registers
Controlling Serial Array Unit.)
phase (For details about the
setting, see 12.3 Registers
Controlling Serial Array Unit.)
Selection of data transfer sequence
0: Inputs/outputs data with MSB first
1: Inputs/outputs data with LSB first.
0: Inputs/outputs data with MSB first
1: Inputs/outputs data with LSB first.
Setting of data length
0: 7-bit data length
1: 8-bit data length
1: 8-bit data length
(c) Serial data register mn (SDRmn) (lower 8 bits: SIOp)
15
14
13
12
11
10
9 8 7 6 5 4 3 2 1 0
SDRmn
Baud rate setting
(Operation clock (f
MCK
) division setting)
0
Transmit data
(Transmit data setting)
(d) Serial output register m (SOm) … Sets only the bits of the target channel.
15
14
13
12
11
10
9 8 7 6 5 4 3 2 1 0
SOm
0
0
0
0
CKOm3
Note 2
0/1
CKOm2
Note 2
0/1
CKOm1
0/1
CKOm0
0/1
0
0
0
0
SOm3
Note 2
0/1
SOm2
Note 2
0/1
SOm1
0/1
SOm0
0/1
Communication starts when these bits are 1 if the clock
phase is non-reversed (the CKPmn bit of the SCRmn = 0).
If the clock phase is reversed (CKPmn = 1),
communication starts when these bits are 0.
phase is non-reversed (the CKPmn bit of the SCRmn = 0).
If the clock phase is reversed (CKPmn = 1),
communication starts when these bits are 0.
Notes 1. Only provided for the SCR00 and SCR01 registers. This bit is fixed to 1 for the other registers.
2.
Unit 0 only
Remarks 1.
m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3),
p: CSI number (p = 00, 01, 10, 11, 20, 21), mn = 00 to 03, 10, 11
2.
: Setting is fixed in the CSI master transmission mode, : Setting disabled (set to the initial value)
0/1: Set to 0 or 1 depending on the usage of the user
SIOp