Figure 12-29.  Flowchart of Master Transmission (in Single-Transmission Mode) 
 
 
Starting CSI communication
Write 1 to STmn bit 
Transmission completed?
No 
Yes 
End of communication
Writing transmit data to 
SIOp (=SDRmn[7:0]) 
When Transfer end interrupt is generated, it 
moves to interrupt processing routine
 
Setting transmit data 
For the initial setting, see Figure 12-26.  
(Select Transfer end interrupt)
 
SAU default setting 
Wait for transmit completes
Transfer end interrupt
Enables interrupt 
Clear interrupt request flag (XXIF), reset interrupt mask (XXMK) and set 
interrupt enable (EI).
 
Disable interrupt (MASK)
Set data for transmission and the number of data.    Clear communication end flag 
(Storage area, Transmission data pointer, Number of communication data and 
Communication end flag are optionally set on the internal RAM by the software)
 
Check completion of transmission by 
verifying transmit end flag
 
Writing to SIOp makes SOp and 
SCKp signals out 
(communication starts)
 
Read transmit data from storage area and write it 
to SIOp.  Update transmit data pointer.
 
Read transmit data, if any, from storage area and 
write it to SIOp.    Update transmit data pointer. 
If not, set transmit end flag
 
Ma
in ro
u
tin
Main
 ro
ut
ine
In
te
rr
up
t p
ro
c
e
s
s
ing
rout
ine
Transmitting next data?
Writing transmit data to 
SIOp (=SDRmn[7:0]) 
No
Sets communication 
completion flag 
RETI 
Yes 
 
 
Remark  m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11 
 
 
<R>