Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
455  
Jul 04, 2013 
(4)  Processing flow (in continuous reception mode) 
 
Figure 12-38.  Timing Chart of Master Reception (in Continuous Reception Mode) (Type 1: DAPmn = 0, CKPmn = 0) 
 
SSmn
SEmn
SDRmn
SCKp pin
SIp pin
INTCSIp
TSFmn
Dummy data
Dummy data
   Write
   Write
Reception & shift operation
BFFmn
<1>
<2>
Dummy data
   Write
MDmn0
Receive data 2
Receive data 1
Receive data 1
Data reception
STmn
Shift
register mn
Read
Read
Read
Receive data 2
Receive data 3
Reception & shift operation
Reception & shift operation
Data reception
Data reception
<2>
<2>
<8>
<5>
<3>
<3>
<4>
<4>
<3>
<6> <7>
Receive data 3
 
 
Caution  The MDmn0 bit can be rewritten even during operation.  
 
However, rewrite it before receive of the last bit is started, so that it has been rewritten before the 
transfer end interrupt of the last receive data. 
 
Remarks 1.  <1> to <8> in the figure correspond to <1> to <8> in Figure 12-39  Flowchart of Master Reception 
(in Continuous Reception Mode). 
 2. 
m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11 
 
<R> 