Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
474  
Jul 04, 2013 
Figure 12-53.  Flowchart of Slave Transmission (in Single-Transmission Mode) 
 
 
Starting CSI communication 
Write 1 to STmn bit 
Continuing transmit? 
Yes 
No 
End of communication 
Writing transmit data to 
SIOp (=SDRmn[7:0]) 
Start communication when master 
start providing the clock 
When transmit end, interrupt is generated 
Wait for transmit completes
For the initial setting, see Figure 12-50.  
(Select transfer end interrupt)
 
SAU default setting
Setting transmit data 
Set storage area and the number of data for transmit data
 
(Storage area, Transmission data pointer, Number of communication data and 
Communication end flag are optionally set on the internal RAM by the software)
Transmitting next data?
 
Yes 
No 
Read transmit data from storage area and write it to SIOp.  Update 
transmit data pointer. 
Enables interrupt 
Clear interrupt request flag (XXIF), reset interrupt mask (XXMK) and set 
interrupt enable (EI). 
Disable interrupt (MASK) 
Determine if it completes by counting number of communication data
Transfer end interrupt 
RETI 
Clear the interrupt request flag (xxIF). 
M
ain rou
tine 
Mai
n routi
ne
In
terr
up
t pro
c
e
s
s
ing
ro
utine
 
 
Remark  m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11 
 
<R>