CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
553  
Jul 04, 2013 
12.8.2  Data transmission 
Data transmission is an operation to transmit data to the target for transfer (slave) after transmission of an address field.  
After all data are transmitted to the slave, a stop condition is generated and the bus is released. 
 
Simplified I
2
IIC00 IIC01 IIC10 IIC11 IIC20 IIC21 
Target channel 
Channel 0 of 
SAU0 
Channel 1 of 
SAU0 
Channel 2 of 
SAU0 
Channel 3 of 
SAU0 
Channel 0 of 
SAU1 
Channel 1 of 
SAU1 
Pins used 
SCL00, 
SDA00
Note  1
 
SCL01, 
SDA01
Note 1 
 
SCL10, 
SDA10
Note 1 
 
SCL11, 
SDA11
Note 1
 
SCL20, 
SDA20
Note 1
 
SCL21, 
SDA21
Note 1
 
INTIIC00 INTIIC01 INTIIC10 INTIIC11 INTIIC20 INTIIC21 
Interrupt 
Transfer end interrupt only (Setting the buffer empty interrupt is prohibited.) 
Error detection flag 
ACK error detection flag (PEFmn) 
Transfer data length 
8 bits 
Transfer rate
Note 2
 Max. 
f
MCK
/4 [MHz] (SDRmn[15:9] = 1 or more) 
f
MCK
: operation clock frequency of target channel 
However, the following condition must be satisfied in each mode of I
2
C. 
•  Max. 1 MHz (first mode plus) 
•  Max. 400 kHz (first mode) 
•  Max. 100 kHz (standard mode) 
Data level 
Non-reversed output (default: high level) 
Parity bit 
No parity bit 
Stop bit 
Appending 1 bit (for ACK reception timing) 
Data direction 
MSB first 
 
Notes 1.  To perform communication via simplified I
2
C, set the N-ch open-drain output (V
DD
 tolerance (25- to 48-pin 
products/EV
DD
 tolerance (64-pin products)) mode (POMxx = 1) for the port output mode registers (POMxx).  
See 4.3  Registers Controlling Port Function and 4.5  Register Settings When Using Alternate Function 
for details.  
 
 
When IIC00, IIC10, IIC20 communicating with an external device with a different potential, set the N-ch open-
drain output (V
DD
 tolerance (25 to 48-pin products/EV
DD
 tolerance (64-pin products)) mode (POMxx = 1) also for 
the clock input/output pins (SCL00, SCL10, SCL20). 
  
See 
4.4.5  Handling different potential (1.8 V, 2.5 V) by using I/O buffers for details. 
 
2.  Use this operation within a range that satisfies the conditions above and the peripheral functions characteristics 
in the electrical specifications (see CHAPTER 29  ELECTRICAL SPECIFICATIONS (T
A
 = 
40 to +85°C) and 
CHAPTER 30  ELECTRICAL SPECIFICATIONS (G: INDUSTRIAL APPLICATIONS T
A
 = 
40 to +105°C)). 
 
Remark 
m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), mn = 00 to 03, 10, 11 
 
<R> 
<R> 
<R>