CHAPTER  13   SERIAL  INTERFACE  IICA 
The following describes the operations in Figure 13-32 (4) Data ~ restart condition ~ address.  After the operations 
in steps <7> and <8>, the operations in steps <i> to <iii> are performed.  These steps return the processing to step 
<iii>, the data transmission step. 
 
<7>  After data transfer is completed, because of ACKE0 = 1, the slave device sends an ACK by hardware to the 
master device.  The ACK is detected by the master device (ACKD0 = 1) at the rising edge of the 9th clock. 
<8>  The master device and slave device set a wait status (SCLA0 = 0) at the falling edge of the 9th clock, and 
both the master device and slave device issue an interrupt (INTIICA0: end of transfer). 
<i> 
The slave device reads the received data and releases the wait status (WREL0 = 1). 
<ii>  The start condition trigger is set again by the master device (STT0 = 1) and a start condition (i.e. SCLA0 =1 
changes SDAA0 from 1 to 0) is generated once the bus clock line goes high (SCLA0 = 1) and the bus data 
line goes low (SDAA0 = 0) after the restart condition setup time has elapsed.  When the start condition is 
subsequently detected, the master device is ready to communicate once the bus clock line goes low 
(SCLA0 = 0) after the hold time has elapsed. 
<iii>  The master device writing the address + R/W (transmission) to the IICA shift register (IICA0) enables the 
slave address to be transmitted. 
 
 