CHAPTER  21   VOLTAGE  DETECTOR 
Table 21-1.  Format of User Option Byte (000C1H/010C1H) (2/2) 
 
Address:  000C1H/010C1H
Note 
 
  7 6 5 4 3 2 1 0 
 VPOC2 
VPOC1 
VPOC0 1 LVIS1 
LVIS0 
LVIMDS1 
LVIMDS0
 
<R> 
•  LVD setting (interrupt mode) 
Detection voltage 
Option byte setting value 
V
LVD
 
Mode setting 
Rising edge  Falling edge 
VPOC2 VPOC1 VPOC0  LVIS1  LVIS0 
LVIMDS1 LVIMDS0
1.67 V 
1.63 V 
1.77 V 
1.73 V 
1.88 V 
1.84 V 
1.98 V 
1.94 V 
2.09 V 
2.04 V 
2.50 V 
2.45 V 
2.61 V 
2.55 V 
2.71 V 
2.65 V 
2.81 V 
2.75 V 
2.92 V 
2.86 V 
3.02 V 
2.96 V 
3.13 V 
3.06 V 
0 1 0 0 
0 1 
− 
Value other than above is setting prohibited. 
 
<R> 
•  LVD off (use of external reset input via RESET pin) 
Detection voltage 
Option byte setting value 
V
LVD
 
Mode setting 
Rising edge  Falling edge 
VPOC2 VPOC1 VPOC0  LVIS1  LVIS0 
LVIMDS1 LVIMDS0
− 
− 
× 
× 
× 
× 
× 
− 
Value other than above is setting prohibited. 
 
Note  Set the same value as 000C1H to 010C1H when the boot swap operation is used because 000C1H is replaced 
by 010C1H. 
 
Cautions  1.  Set bit 4 to 1. 
 
2.  After power is supplied, the reset state must be retained until the operating voltage becomes in 
the range defined in 29.4 or 30.4  AC Characteristics.  This is done by utilizing the voltage 
detector or controlling the externally input reset signal.  After the power supply is turned off, this 
LSI should be placed in the STOP mode, or placed in the reset state by utilizing the voltage 
detector or controlling the externally input reset signal, before the voltage falls below the 
operating range.   
<R> 
 
  The range of operating voltage varies with the setting of the user option byte (000C2H or 010C2H).  
 
Remarks 1. 
×: don’t care 
 
2.  For details on the LVD circuit, see CHAPTER 21  VOLTAGE DETECTOR
 
3.  The detection voltage is a TYP. value.  For details, see 29.6.4 or 30.6.4  LVD circuit characteristics
 