Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  30   ELECTRICAL  SPECIFICATIONS  (G:  INDUSTRIAL  APPLICATIONS  T
A
  =  
−40  to  +105°C) 
R01UH0305EJ0200  Rev.2.00 
 
 
931  
Jul 04, 2013 
(5)  Communication at different potential (1.8 V, 2.5 V) (UART mode) (dedicated baud rate generator output) (1/2) 
(T
A
 = 
40 to +105°C, 2.4 V  EV
DD0
 
 V
DD
 
 3.6 V, V
SS
 = EV
SS0
 = 0 V)  
Parameter Symbol 
Conditions 
MIN. TYP. 
MAX.
Unit 
 
 
 
f
MCK
/12
bps 
2.7 V 
≤ EV
DD0
 
≤ 3.6 V, 
2.3 V 
≤ V
b
 
≤ 2.7 V 
Theoretical value of the 
maximum transfer rate 
f
CLK
 = 32 MHz, f
MCK
 = f
CLK
 
  
2.6 
Mbps
 
 
 
f
MCK
/12
bps 
Transfer rate
Note 1
 
 
 
 
 
 
 
 Reception 
2.4 V 
≤ EV
DD0
 < 3.3 V, 
1.6 V 
≤ V
b
 
≤ 2.0 V 
Theoretical value of the 
maximum transfer rate 
f
CLK
 = 32 MHz, f
MCK
 = f
CLK
 
  
2.6
Note 2
Mbps
 
Notes 1.  Transfer rate in the SNOOZE mode is 4800 bps. 
 
2.  The following conditions are required for low-voltage interface when EV
DD0
 < V
DD
2.4 V 
≤ EV
DD0
 < 2.7 V : MAX. 1.3 Mbps 
 
Caution  Select the TTL input buffer for the RxDq pin and the N-ch open drain output (V
DD
 tolerance (When 25- to 
48-pin products)/EV
DD
 tolerance (When 64-pin products)) mode for the TxDq pin by using port input 
mode register g (PIMg) and port output mode register g (POMg).  For V
IH
 and V
IL
, see the DC 
characteristics with TTL input buffer selected. 
 
Remarks  1.  V
b
[V]: Communication line voltage 
 2. 
q: UART number (q = 0 to 2), g: PIM and POM number (g = 0, 1) 
 3. 
f
MCK
: Serial array unit operation clock frequency  
(Operation clock to be set by the CKSmn bit of serial mode register mn (SMRmn). m: Unit number,  
n: Channel number (mn = 00 to 03, 10, 11) 
 
<R>