Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
APPENDIX  A   REVISION  HISTORY 
(4/5) 
Page Description 
Classification
CHAPTER  18   STANDBY FUNCTION 
p.758 Modification 
of 
Table 18-1. Operating Statuses in HALT Mode 
(c) 
p.760, 761 
Modification of figure and note in Figure 18-4.  HALT Mode Release by Reset (c) 
p.762 Modification 
of 
caution 1 in 18.3.2 (1) STOP mode setting and operating statuses 
(c) 
p.764 Deletion 
of 
caution 1 in Table 18-2. Operating Statuses in STOP Mode  (c) 
p.764, 765 
Modification of note 2 and addition of remark 2 to Figure 18-5. STOP Mode Release by Interrupt 
Request Generation 
(c) 
p.766 
Modification of figure and note in Figure 18-6.  STOP Mode Release by Reset (c) 
p.767 
Modification of description in 18.3.3 (1) SNOOZE mode setting and operating statuses 
(c) 
CHAPTER  19   RESET FUNCTION 
p.769 
Modification of description and cautions 1, 3 in CHAPTER 19  RESET FUNCTION (c) 
p.771, 772 
Modification of figure and note 2 in Figures 19-219-3 (c) 
p.773 
Modification of description in Table 19-1. Operation Statuses During Reset Period 
(c) 
p.774 
Modification of description and  note 2 in Table 19-2.  Hardware Statuses After Reset 
Acknowledgment 
(c) 
CHAPTER  20   POWER-ON-RESET  CIRCUIT 
p.781 
Modification of description and addition of note to 20.1 Functions of Power-on-reset Circuit 
(c) 
p.783 to 785 
Modification of figure and notes in Figure 20-2. Timing of Generation of Internal Reset Signal by 
Power-on-reset Circuit and Voltage Detector 
(c) 
CHAPTER  21   VOLTAGE DETECTOR 
p.788 
Modification of description in 21.1 Functions of Voltage Detector 
(c) 
p.795 Modification 
of 
Figure 21-4. Timing of Voltage Detector Internal Reset Signal Generation (Option 
Byte LVIMDS1, LVIMDS0 = 1, 1) 
(c) 
p.796 Addition 
of 
note to 21.4.2 When used as interrupt mode (c) 
p.797 
Modification of figure and addition of notes 2, 3 to Figure 21-5. Timing of Voltage Detector Internal 
Interrupt Signal Generation (Option Byte LVIMDS1, LVIMDS0 = 0, 1) 
(c) 
p.798 Addition 
of 
note to 21.4.3 When used as interrupt and reset mode 
(c) 
p.799 to 802 
Modification of figure and addition of note 4 to Figure 21-6. Timing of Voltage Detector Reset 
Signal and Interrupt Signal Generation (Option Byte LVIMDS1, LVIMDS0 = 1, 0) 
(c) 
p.802 Modification 
of 
Figure 21-7. Processing Procedure After an Interrupt Is Generated 
(c) 
p.803 Modification 
of 
Figure 21-8. Initial Setting of Interrupt and Reset Mode 
(c) 
CHAPTER  22   SAFETY FUNCTIONS 
p.806 Modification 
of 
remark in 22.1 Overview of Safety Functions (c) 
p.812 Modification 
of 
caution and remarks 1 to 4 in Figure 22-7. Format of RAM Parity Error Control 
Register (RPECTL) 
(c) 
p.815 
Addition of figure and note to Figure 22-10. Invalid access detection area 
(c) 
CHAPTER  24   OPTION BYTE 
p.824 
Modification of description and addition of caution to 24.1 Functions of Option Bytes (c) 
p.825 
Modification of description in 24.1.1  User option byte (000C0H to 000C2H/010C0H to 010C2H) (c) 
p.826 Modification 
of caution in Figure 24-1. Format of User Option Byte (000C0H/010C0H) 
(c) 
p.827, 828 
Addition of caution 2 to Figure 24-2. Format of User Option Byte (000C1H/010C1H) 
(c) 
p.829 
Modification of description and caution in Figure 24-3. Format of User Option Byte 
(000C2H/010C2H) 
(c) 
Remark  “Classification” in the above table classifies revisions as follows. 
 
(a): Error correction, (b): Addition/change of specifications, (c): Addition/change of description or note,  
(d): Addition/change of package, part number, or management division, (e): Addition/change of related 
documents 
R01UH0305EJ0200  Rev.2.00 
 
 
972  