Elmo DSP 402 User Manual

Page of 116
Object 0x6075: Motor Rate Current  
This value is taken from the motor nameplate and is entered in multiples of milliamp. 
Depending on the motor and drive technology this current may be either DC, peak or 
rms (root-mean-square) current. All relative current data refers to this value. 
 
Object description: 
Index 6075h 
Name 
Motor Rate Current 
Object code 
VAR 
Data type 
UNSIGNED32 
Category Mandatory 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
UNSIGNED32 
Default value 
Note: This value of 6075h is set to CL[1] after it is converted to Amperes. 
Object 0x6076: Motor Rate Torque  
This value is taken from the motor name plate and is entered as a multiple of mNm 
(mill wtonmeter). All relative torque data refer to this value. 
For linear motors, the object name is not changed, but the motor rated force value 
must be entered as a multiple of mN (mill Newton).. 
 
Object description: 
Index 6076h 
Name 
Motor Rate Torque 
Object code 
VAR 
Data type 
UNSIGNED32 
Category Mandatory 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
UNSIGNED32 
Default value 
 
CANopen DSP 402 Implementation Guide 
 
MAN-CAN402IG (Ver. 1.2) 
 
 
106