Communication Manager Maintenance-Object Repair Procedures
1044 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Response to the test was not received within the allowable time period. This 
may be due to hyperactivity. Error type 1538 in the error log indicates 
hyperactivity. The hyperactive circuit pack is out of service and one or more 
of the following symptoms may be exhibited.
The DS1-BD tests (such as test 138 and test 139) are aborting with 
error code 2000.
The tests run on the ports of this circuit pack are returning a no board 
result.
busyout or a release command has no affect on the test results.
list config command shows that the circuit pack and the ports 
are properly installed.
When hyperactivity occurs, the circuit pack is isolated from the system, and 
all of its trunks are placed into the out-of-service state. The system will try to 
restore the circuit pack within 15 minutes. When no faults are detected for 15 
minutes, the DS1 interface circuit pack is restored to normal operation. Every 
DS1 interface trunk is then returned to the in-service state. Hyperactivity is 
often caused by the associated facility. In such a case, faults (such as slips, 
misframes, or blue alarms) would be entered in the error log. In addition, 
many hardware errors would be logged against the associated trunk circuits. 
If the facility is OK and the error occurs again after 15 minutes, escalate this 
problem.
G700
FAIL
Test was run between a TN464 and an MM710, which generate incompatible 
patterns. 
 
PASS
The One-Way Span test has successfully began transmitting a framed 
3-in-24 test pattern. The test will continue to run until the system technician 
enters test ds1-loop location end-loopback/span-test or 
release board location.
Table 358: Test #1214 One-Way Span Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 4