Communication Manager Maintenance-Object Repair Procedures
1072 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
DS1 Interface Options Audit Test (#798)
This test is nondestructive.
This test sends the administered DS1 Interface options to the DS1 converter circuit pack. 
Options are sent to both DS1 converter circuit packs at the same time to prevent any 
transitional mismatch of options.
The following DS1 facility options are sent to the TN574 DS1 converter circuit pack: Framing 
Mode, Line Coding and DS1 converter-1 and DS1 converter-2 Line Compensation.
The following DS1 facility options are sent to the TN1654 DS1 converter circuit pack: Line 
Coding and DS1 converter-1 and DS1 converter-2 Line Compensation (T1 only). These option 
fields appear on the Fiber-link Administration screen.
Table 366: Test #798 DS1 Interface Options Audit 
Error 
Code
Test 
Result
Description / Recommendation
105
ABRT
The neighbor DS1 converter circuit pack at the other end of the DS1 
converter complex is not accessible.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2000
ABRT
Timed out while waiting for a response from the circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316
ABRT
Fiber link is not administered. Use add fiber-link to administer the 
DS1 converter fiber link.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS
The DS1 Interface options are sent to the circuit pack.