DS1 Facilities Connectivity Test (#790)
This test is destructive.
The DS1 facilities connectivity test will check the correct connectivity of the DS1 facilities at 
opposite ends of the DS1 converter complex. Every part of this test is executed under firmware 
control and the result is sent back to the maintenance software.
For TN574 DS1 Converter circuit packs, this test is executed by sending digital data through 
each time slot of every DS1 facility channel. Two different test patterns are used, these are 
hexadecimal values 55 and AA.
For TN1654 DS1 Converter circuit packs, this test has been enhanced to provide error codes 
that point to the exact fault. Rather than simply reporting a failure of the connectivity test, the 
TN1654 test specifically identifies the two DS1 facilities that are cross-connected at the near 
and far ends of the DS1 converter complex. In addition, a fault code will indicate the condition of 
not being able to loop-up the far end, as required to run the test, due to the packet DS1 facility 
being down.
The TN1654 connectivity test sends digital data through only one time slot. Instead of looping 
back the facility to itself, the TN1654 version of the test loops-up the other three facilities. If the 
test pattern comes back, the firmware fails the test due to an incorrect connection between DS1 
facilities. It should be noted that this test will pass and give no indication of problems if the 
non-packet facilities are down.
For a standard-, duplex-, or high-reliability system (no PNC duplication), this test can only be 
executed at the endpoint that is closer to the media server relative to the neighbor DS1 
converter circuit pack because of its impacts on the system control links. In addition, for TN574 
DS1 converter boards, the completion of the test will be delayed in this configuration to wait for 
the recovery of the system control links. For a critical-reliability system (PNC duplication), test 
can be executed at any DS1 converter circuit pack.
Table 377: Test #790 DS1 Facilities Connectivity Loop-Back Test 
Error 
Code
Test 
Result
Description / Recommendation
2000
ABRT
Timed out while waiting for a response from the circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
 1 of 3