Avaya 03-300430 User Manual

Page of 2574
ETH-PT (Control LAN Ethernet)
Issue 1 June 2005
1159
 
1125
ABRT
Ethernet link not in service.
1. Verify Ethernet link is in service (status port location or 
status link n).
2. If the link is not in service, release the link using (release link n or 
release port location).
3. Repeat the test.
4. Escalate if the problem persists.
2000
ABRT
Did not receive circuit pack test response within the allowable time period.
1. Reset the circuit pack (busyout board locationreset board 
location, and release board location).
2. If the test fails again, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100
ABRT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1003
FAIL
Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, reset the circuit pack (busyout board 
locationreset board location, and release board 
location
).
3. If the problem persists, re-administer the Ethernet connection through 
a different Ethernet port, if available.
4. If the problem still persists, or if there are no other available Ethernet 
ports, replace the circuit pack.
Table 398: Test #1281 TCP/IP Ping Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3