Avaya 03-300430 User Manual

Page of 2574
ETH-PT (Control LAN Ethernet)
Issue 1 June 2005
1161
 
1125
ABRT
Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port location 
or status link n).
2. If the Ethernet link is not in service, release the link (release link 
n or release port location).
3. Repeat the test.
4. Escalate if the problem persists.
1959
ABRT
Downlink message error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100
ABRT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
FAIL
Link integrity lost due to problem with attachment of Ethernet cable to the 
port.
1. Repeat the test.
2. If the test fails, verify that the cable properly is secured to Ethernet port 
and to the bus.
3. Verify the C-LAN circuit pack’s link integrity LED is glowing.
4. Retry the test.
5. If problem persists, see Ethernet Local Loop-around test (#1278) 
repair procedures.
PASS
The Ethernet Link Integrity test (#1282) detects good connections.
Table 399: Test #1282 Link Integrity Inquiry Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2