Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1268 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
105
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped 
SNI in slot 5. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 769, replace the SNI 
being tested. (Replacing an SNI may be service interrupting. Refer to 
the SNI-BD section for the procedure to replace an SNI.) To view 
SNI-PEER errors, use display errors with category PNC-PEER. 
Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 769, replace the SNI 
in slot 5.
106
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped 
SNI in slot 6. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the 
 in 
 in Maintenance Procedures (03-300192). This should 
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1025, replace the 
SNI being tested. (Replacing an SNI may be service interrupting. 
Refer to the SNI-BD section for the procedure to replace an SNI.) To 
view SNI-PEER errors, use display errors with category 
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 1025, replace 
the SNI in slot 6.
Table 440: Test #759 Configuration Audit  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 22