Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
1268 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
105
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped
SNI in slot 5. Use list fiber-link to see a fiber link’s endpoints.
SNI in slot 5. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the
in
in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 769, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to
the SNI-BD section for the procedure to replace an SNI.) To view
SNI-PEER errors, use display errors with category PNC-PEER.
the SNI-BD section for the procedure to replace an SNI.) To view
SNI-PEER errors, use display errors with category PNC-PEER.
Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 769, replace the SNI
in slot 5.
106
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped
SNI in slot 6. Use list fiber-link to see a fiber link’s endpoints.
SNI in slot 6. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the
in
in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1025, replace the
SNI being tested. (Replacing an SNI may be service interrupting.
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 1025, replace
the SNI in slot 6.
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
4 of 22